Hoshizaki KM-650MAH instruction manual Cleaning Procedure

Page 27

1.Cleaning Procedure

1)Dilute 16 fl. oz. (473 ml) of recommended cleaner Hoshizaki "Scale Away" or "LIMEAWAY" (Economics Laboratory, Inc.) with 3 gal. ( 11 l) of warm water.

2)Remove all ice from the evaporator and the storage bin.

Note: To remove cubes on the evaporator, turn off the power supply and turn it back on after 3 minutes. The harvest cycle starts and the cubes will be removed from the evaporator.

3)Turn off the power supply.

4)Remove the front panel, then remove the insulation panel by lifting up the panel slightly and pulling it towards you.

5)Remove the base cover, then disconnect one end of the pump tubing to drain the water tank. See Fig. 14. After the water tank has drained, reconnect the pump tubing.

6)In bad or severe water conditions, clean the float switch assembly as described below. Otherwise, continue to step 7.

a.Disconnect the vent tube and the flush tube from the top of the float switch, then remove the float switch assembly. Remove the rubber boot from the bottom of the assembly.

b.Remove the retainer rod from the bottom of the float switch housing, then remove the float. Be careful not to bend the retainer rod excessively when removing it.

c.Wipe down the float switch housing, shaft, float, and retainer rod with cleaning solution. Clean the inside of the rubber boot and hose with cleaning solution. Rinse the parts thoroughly with clean water.

d.Reassemble the float switch assembly and replace it and the rubber boot in their correct positions. Reconnect the vent tube and the flush tube.

7)Pour the cleaning solution into the water tank.

8)Fully open the cleaning valve on the left side wall of the machine compartment.

9)Move the control switch on the control box to the "WASH" position.

10)Replace the insulation panel and the front panel in their correct positions.

11)Turn on the power supply to start the washing process.

12)Turn off the power supply after 30 minutes.

13)Remove the front panel.

14)Disconnect one end of the pump tubing to drain the water tank. After the water tank has drained, reconnect the pump tubing.

15)Move the control switch to the "ICE" position.

16)Close the cleaning valve.

Note: The icemaker will not operate unless the cleaning valve is completely closed.

17)Replace the front panel in its correct position.

18)Turn on the power supply to fill the water tank with water.

19)Turn off the power supply after 3 minutes.

20)Remove the front panel and fully open the cleaning valve.

27

Image 27
Contents KM-650MAH KM-650MWH KM-650MRH Hoshizaki AMERICA, INC Contents Important Safety Information KM-650MAH air-cooled Specifications Nameplate RatingMAX. Hacr Breakerusa only Amps KM-650MWH water-cooledKM-650MRH remote air-cooled KM-650MAH Dimensions / ConnectionsKM-650MWH KM-650MRH II. Installation and Operating Instructions Checks Before InstallationHow to Remove Panels See Fig Location SetupElectrical Connection For All ModelsAdditional Warnings for Remote Air-Cooled Model Installation of Remote Condenser Unit Checks Before InstallationLocation Line Set SetupField Fabricated Line Set Installation Ester Electrical Connection Stacking Remote Condenser Units See , 12, or Water Supply and Drain ConnectionsIcemaker KM-650MAH and KM-650MRHConnection to an Open Drain System Water-Cooled CondenserKM-650MWH Final Checklist Startup Cleaning and Sanitizing Instructions III. Cleaning and MaintenanceCleaning Procedure Sanitizing Procedure Following Cleaning Procedure Air Filters air-cooled model MaintenanceStainless Steel Exterior Storage Bin and ScoopPreparing the Icemaker for Long Storage Remove the water from the icemaker water supply lineDrain the water tank Page Hoshizaki AMERICA, INC