Hoshizaki F-80 I MAH (-c), F-80 I MWH (-c) service manual Performance Data, F-801MAH

Page 29

5. Performance Data

F-801MAH

APPROXIMATE

Ambient

 

 

 

 

Water Temp.

 

(F)

 

ICE PRODUCTION

Temp. (F)

 

50

 

 

70

 

 

 

90

 

PER 24 HR.

70

*

823

(373)

 

786

(357)

 

 

748

(339)

 

80

 

711

(323)

 

677

(307)

 

 

644

(292)

 

90

 

613

(278)

*

599

(272)

 

 

555

(252)

lbs./day ( kg/day)

100

 

528

(239)

 

502

(228)

 

*

471

(214)

APPROXIMATE ELECTRIC

70

*

1089

--

 

1095

--

 

 

1101

--

CONSUMPTION

80

 

1107

--

 

1113

--

 

 

1119

--

 

90

 

1125

--

*

1131

--

 

 

1147

--

watts

100

 

1164

--

 

1181

--

 

*

1197

--

APPROXIMATE WATER

70

*

99

(374)

 

94

(357)

 

 

90

(340)

CONSUMPTION PER 24 HR.

80

 

85

(323)

 

81

(308)

 

 

77

(293)

(TOTAL)

90

 

74

(278)

*

72

(272)

 

 

67

(252)

gal. / day (l/day)

100

 

63

(240)

 

60

(228)

 

*

57

(214)

EVAPORATOR OUTLET TEMP.

70

*

15

(-10)

 

16

(-9)

 

 

16

(-9)

°F (°C)

80

 

16

(-9)

 

16

(-9)

 

 

17

(-8)

 

90

 

17

(-8)

*

17

(-8)

 

 

18

(-8)

 

100

 

19

(-7)

 

19

(-7)

 

*

20

(-7)

HEAD PRESSURE

70

*

204

(14.3)

 

266

(18.7)

 

 

302

(21.2)

 

80

 

204

(14.3)

 

266

(18.7)

 

 

302

(21.2)

PSIG (kg/cm2G)

90

 

204

(14.3)

*

266

(18.7)

 

 

302

(21.2)

100

 

204

(14.3)

 

266

(18.7)

 

*

302

(21.2)

SUCTION PRESSURE

70

*

38

(2.7)

 

42

(3.0)

 

 

46

(3.3)

PSIG (kg/cm2G)

80

 

38

(2.7)

 

42

(3.0)

 

 

46

(3.3)

 

90

 

38

(2.7)

*

42

(3.0)

 

 

46

(3.3)

 

100

 

38

(2.7)

 

42

(3.0)

 

*

46

(3.3)

TOTAL HEAT OF REJECTION

 

6398 BTU/h (AT

90°F / WT 70°F)

 

 

 

 

Note: The data without *marks should be used for reference.

We reserve the right to make changes in specifications and design without prior notice.

29

Image 29
Contents “A Superior Degree of Reliability” Number Issued RevisedModular Flaker Models F-801MAH-C F-801MWH-C HoshizakiHoshizaki America, IncComplete and detailed explanation of the problem Phone 1-800-233-1940 Technical Service 770 487-2331 FaxHOSHIZAKI AMERICA, INC 618 Highway 74 South Peachtree City, GA Attn HOSHIZAKI Technical Support DepartmentCONTENTS 7. Removal and Replacement of Evaporator Assembly 5. Removal and Replacement of Expansion Valve8. Removal and Replacement of Fan Motor 9. Removal and Replacement of Control Water ValveF-801MAH I. Specification 1. IcemakerF-801MWH F-801MAH-C F-801MWH-C F-801MAH/-C II. General Information 1. ConstructionWater Supply Inlet Junction Box Water Regulator Compressor Drier F-801MWH/-CGEAR MOTOR 2. Control Box LayoutRUN CAPACITOR CONTROL TIMERFLUSH III. Technical Information 1. Water Circuit and Refrigeration Circuit F-801MWH/-C F-801MAH/-C, F-801MWH/-C 2. Wiring Diagrams3. Sequence of Electrical Circuit b When reservoir has been filled, gear motor starts immediately c Compressor starts about 60 sec. after gear motor starts Page e Low water except water-cooled model Page Page h When flush timer operates for 15 min. every 12 hours Page Page Proper wiring. The unit starts 4. Timing Chart Miswiring. Circuit Protect Relay operates 60 sec 150 sec1 sec 1. CIRCUIT PROTECT RELAY 2. WATER LEVEL UPPER 3. FLOAT SWITCH LOWER 5. Performance Data WATER FLOW FOR CONDENSER F-801MAH-C F-801MWH-C 1. Adjustment of Water Regulating Valve water-cooled model only IV. Adjustment of Components2. Adjustment of Flake Size PROBLEM V. Service Diagnosis 1. No Ice ProductionPOSSIBLE CAUSE REMEDYREMEDY 2. Low Ice Production PROBLEMPOSSIBLE CAUSE REMEDY3. Other 1. Service for Refrigerant Lines VI. Removal and Replacement of Componentsa Refrigerant Recovery b Evacuation and Recharge R-404A2. Brazing DANGER 3. Removal and Replacement of Compressor 4. Removal and Replacement of Drier 5. Removal and Replacement of Expansion Valve Page Cutter 7. Removal and Replacement of Evaporator AssemblyExtruding Head AugerGear Motor Bearing-Lower and Mechanical Sealc Check for leaks using nitrogen gas 140 PSIG and soap bubbles 27 When replacing the evaporator28 Move the flush switch to the ICE position 30 Turn on the power supplyCoupling - Spline Auger Mechanical Seal O-ring Bearing Lower Bolt WasherRubber O-ring Nylon Ring Bolt Washer Cutter Extruding Head Washer Socket Head Cap Screw Evaporator Washer Socket Head Cap Screw Barrier9. Removal and Replacement of Control Water Valve 8. Removal and Replacement of Fan Motor10. Removal and Replacement of Flush Water Valve 1. Preparing the Icemaker for Long Storage VII. Cleaning and Maintenancea Cleaning Solution 2. Cleaning and Sanitizing Instructionsb Cleaning Procedure d Sanitizing Procedure - Initial c Sanitizing Solutione Sanitizing Procedure - Final 19 Turn off the power supply after 30 minutes 18 Move the flush switch to the “ICE” position and run the icemaker21 Flush out any solution from the storage bin 22 Turn on the power supply and start the automatic icemaking process3. Maintenance 4 Condenser except water-cooled model 3 Air Filter air-cooled model only