13)Recover the refrigerant and store it in an approved container, if required by an applicable law.
IMPORTANT
Always install a new drier every time the sealed refrigeration system is opened. Do not replace the drier until after all other repairs or replacement have been made.
14)Remove the bulb of the expansion valve.
15)Disconnect the
16)Remove the two truss head machine screws and the strap securing the evaporator.
17)Disconnect the three hoses from the evaporator.
18)Remove the four socket head cap screws securing the evaporator with the bearing- lower.
19)Lift off the evaporator.
Bearing-Lower and Mechanical Seal
20)The mechanical seal consists of two parts. One moves along with the auger, and the other is fixed on the
21)Remove the
22)Remove the four bolts and the
Note: Replacing the bearing requires a bearing press adaptor. If it is not available, replace the whole
Gear Motor
23)Remove the
24)Remove the barrier on the top of the gear motor.
25)Remove the three socket head cap screws securing the gear motor. 46