2. Low Ice Production
PROBLEM |
| POSSIBLE CAUSE |
| REMEDY | ||
[1] Low ice production | a) | Refrigerant Line | 1. | Gas leaks. | 1. | See "1. [5] a) |
|
|
|
|
|
| Refrigerant Line." |
|
|
| 2. | Refrigerant line | 2. | Replace the clogged |
|
|
|
| clogged. |
| component. |
|
|
| 3. | Overcharged. | 3. | Recharge. |
|
|
|
|
|
|
|
| b) | 1. | Dirty Air Filter or | 1. | Clean. | |
|
| Too High |
| Condenser. |
|
|
|
|
| 2. | Ambient or | 2. | Get cooler. |
|
|
|
| condenser water |
|
|
|
|
|
| temperature too |
|
|
|
|
|
| warm. |
|
|
|
|
| 3. | Condenser water | 3. | Check and get |
|
|
|
| pressure too low or |
| recommended |
|
|
|
| off. |
| pressure. |
|
|
|
| model only] |
|
|
|
|
| 4. | Fan rotating too | 4. | See "3 [1] a) Fan |
|
|
|
| slow. |
| Motor." |
|
|
| 5. | Water Regulating | 5. | Clean. |
|
|
|
| Valve clogged. |
|
|
|
|
|
|
|
| |
|
|
|
| only] |
|
|
|
|
| 6. | Condensing unit out | 6. | Check condensing |
|
|
|
| of order. |
| unit. |
| c) | Expansion Valve | 1. | 1. | Replace. | |
|
| (not adjustable) |
| too low. |
|
|
|
|
| 2. | 2. | See if Expansion | |
|
|
|
| too high. |
| Valve Bulb is mounted |
|
|
|
|
|
| properly, and replace |
|
|
|
|
|
| the valve if necessary. |
|
|
|
|
|
|
|
37