8.Removal and Replacement of Fan Motor
1)Turn off the power supply and remove the panels.
2)Remove the wire connectors from the fan motor leads.
3)Remove the fan motor bracket and fan motor.
4)Install the new fan motor.
5)Replace the fan motor bracket and the wire connectors.
6)Replace the panels in their correct position, and turn on the power supply.
9.Removal and Replacement of Control Water Valve
1)Turn off the power supply, remove the panels and close the water supply line
2)Disconnect the terminals from the control water valve.
3)Loosen the fitting nut on the control water valve inlets, and remove the control water valve. Do not lose the packings inside the fitting nut.
4)Remove the water supply hose from the control water valve.
5)Install the new control water valve.
6)Assemble the removed parts in the reverse order of the above procedure.
7)Open the water supply line
8)Check for water leaks.
9)Replace the panels in their correct position, and turn on the power supply.
49