[e] Sanitizing Procedure - Final

14) Replace all parts in their correct positions.

IMPORTANT

When installing the baffles, make sure that the bent surface (the one without the studs) faces the actuator so that the bent surface can guide the ice to the center of the actuator.

15)Move the flush switch to the “ICE” position, then turn on the power supply. Replace the top panel and front panel in their correct positions. Make ice using the solution until the icemaker stops making ice.

[e] Sanitizing Procedure - Final

1)Remove the front panel and top panel, then turn off the power supply.

2)Move the flush switch to the “FLUSH” position.

3)Turn on the power supply and drain out all water from the water line.

4)Turn off the power supply.

5)Remove the strap connecting the spout to the chute assembly.

6)Remove the thumbscrews securing the spout and lift it off.

7)Pour the sanitizing solution over the extruding head until the evaporator assembly and the reservoir are filled and the solution starts to overflow into the drain pan.

8)Replace the spout and strap in their correct positions.

9)Allow the icemaker to sit for about 10 minutes before operation.

10)Move the flush switch to the “ICE” position, then turn on the power supply. Replace the top panel and front panel in their correct positions. Make ice using the solution until the icemaker stops making ice.

11)Remove the front panel.

12)Move the flush switch to the “FLUSH” position to drain the remainder of the solution.

13)After the solution is drained, move the flush switch to the “ICE” position.

14)Replace the front panel in its correct position.

15)Open the water supply line shut-off valve and supply water to the reservoir.

55

Image 55
Contents HoshizakiHoshizaki America, Inc Number Issued Revised“A Superior Degree of Reliability” Modular Flaker Models F-801MAH-C F-801MWH-CAttn HOSHIZAKI Technical Support Department Phone 1-800-233-1940 Technical Service 770 487-2331 FaxComplete and detailed explanation of the problem HOSHIZAKI AMERICA, INC 618 Highway 74 South Peachtree City, GACONTENTS 9. Removal and Replacement of Control Water Valve 5. Removal and Replacement of Expansion Valve7. Removal and Replacement of Evaporator Assembly 8. Removal and Replacement of Fan MotorF-801MAH I. Specification 1. IcemakerF-801MWH F-801MAH-C F-801MWH-C F-801MAH/-C II. General Information 1. ConstructionWater Supply Inlet Junction Box Water Regulator Compressor Drier F-801MWH/-CGEAR MOTOR 2. Control Box LayoutFLUSH CONTROL TIMERRUN CAPACITOR III. Technical Information 1. Water Circuit and Refrigeration Circuit F-801MWH/-C F-801MAH/-C, F-801MWH/-C 2. Wiring Diagrams3. Sequence of Electrical Circuit b When reservoir has been filled, gear motor starts immediately c Compressor starts about 60 sec. after gear motor starts Page e Low water except water-cooled model Page Page h When flush timer operates for 15 min. every 12 hours Page Page Miswiring. Circuit Protect Relay operates 4. Timing ChartProper wiring. The unit starts 1 sec 150 sec60 sec 1. CIRCUIT PROTECT RELAY 2. WATER LEVEL UPPER 3. FLOAT SWITCH LOWER 5. Performance Data WATER FLOW FOR CONDENSER F-801MAH-C F-801MWH-C 1. Adjustment of Water Regulating Valve water-cooled model only IV. Adjustment of Components2. Adjustment of Flake Size REMEDY V. Service Diagnosis 1. No Ice ProductionPROBLEM POSSIBLE CAUSEPOSSIBLE CAUSE REMEDY PROBLEM2. Low Ice Production POSSIBLE CAUSE3. Other b Evacuation and Recharge R-404A VI. Removal and Replacement of Components1. Service for Refrigerant Lines a Refrigerant Recovery2. Brazing DANGER 3. Removal and Replacement of Compressor 4. Removal and Replacement of Drier 5. Removal and Replacement of Expansion Valve Page Auger 7. Removal and Replacement of Evaporator AssemblyCutter Extruding HeadGear Motor Bearing-Lower and Mechanical Seal30 Turn on the power supply 27 When replacing the evaporatorc Check for leaks using nitrogen gas 140 PSIG and soap bubbles 28 Move the flush switch to the ICE positionSocket Head Cap Screw Evaporator Washer Socket Head Cap Screw Barrier Auger Mechanical Seal O-ring Bearing Lower Bolt WasherCoupling - Spline Rubber O-ring Nylon Ring Bolt Washer Cutter Extruding Head Washer9. Removal and Replacement of Control Water Valve 8. Removal and Replacement of Fan Motor10. Removal and Replacement of Flush Water Valve 1. Preparing the Icemaker for Long Storage VII. Cleaning and Maintenancea Cleaning Solution 2. Cleaning and Sanitizing Instructionsb Cleaning Procedure d Sanitizing Procedure - Initial c Sanitizing Solutione Sanitizing Procedure - Final 22 Turn on the power supply and start the automatic icemaking process 18 Move the flush switch to the “ICE” position and run the icemaker19 Turn off the power supply after 30 minutes 21 Flush out any solution from the storage bin3. Maintenance 4 Condenser except water-cooled model 3 Air Filter air-cooled model only