Manitowoc Ice QM30 Series specifications Section Ice Machine Operation, Sequence of Operation

Page 15

Section 3

Ice Machine Operation

 

Section 3

 

Ice Machine Operation

Sequence of Operation

 

Ice Making

 

Control Board Relays

 

 

 

1

2

 

3

Length of

 

Sequence of

Compressor

Hot Gas Valve

 

Water Pump

 

 

“ON” Time

 

Operation

Water Fill Valve

 

Fan Motor

 

 

 

 

Start-Up1

Off

On

 

Off

2.9 Minutes

1.

Water Purge

 

(175 Seconds)

 

 

 

 

2.

Refrigeration

On

On

 

Off

5 Seconds

 

System Start-Up

 

 

 

 

 

 

 

3.

Freeze Cycle

On

Off

 

On

Automatically

 

determined

 

 

 

 

 

 

4.

Harvest Cycle

On

On

 

Off

Automatically

 

determined

 

 

 

 

 

 

5.

Auto Shut-Off

Off

Off

 

Off

Until bin thermostat

 

re-closes

 

 

 

 

 

 

1Initial Start-Up or Start-Up After Automatic Shut-Off

INITIAL START-UP OR START-UP AFTER AUTOMATIC SHUT-OFF

1. Water Purge

The water fill valve and the hot gas valve are energized for 2.9 minutes (175 seconds). This ensures that the ice making cycle starts with fresh water, and that the refrigerant pressures are equalized prior to refrigeration system start-up.

2. Refrigeration System Start-Up

The compressor starts 2.9 minutes (175 seconds) after the water fill valve and hot gas valve are energized. (The water fill valve and hot gas valve remain energized for 5 seconds during compressor start-up, and then shut off.) The compressor remains on throughout the entire freeze and harvest cycles.

3. Freeze Cycle

The condenser fan motor and water pump are energized and remain on throughout the entire freeze cycle. An even flow of water is directed across the evaporator and into each cube cell, where it freezes.

The control system automatically determines the length of the freeze cycle by monitoring the temperature of the refrigeration system liquid line.

4. Harvest Cycle

The condenser fan motor and water pump de- energize. The water fill valve energizes to purge the water in the water trough. The hot gas valve also energizes at the beginning of the harvest cycle to divert hot refrigerant gas into the evaporator. The hot refrigerant gas warms the evaporator, causing the cubes to slide, as a sheet, off the evaporator and into the ice storage bin.

The control system automatically determines the length of the harvest cycle, based on the temperature of the refrigeration system liquid line at the end of the freeze cycle. At the end of the harvest cycle, the ice machine returns to another freeze cycle (step 3, above).

5. Automatic Shut-Off

The level of ice in the ice storage bin controls the ice machine shut-off. When the bin is full, ice cubes contact the bin thermostat bulb holder, which cools down and opens to stop the ice machine. The ice machine remains off until enough ice has been removed from the bin. This causes the thermostat bulb holder to warm and close, restarting the ice machine. When the ice machine restarts, it returns to the start-up sequence (steps 1 and 2, above).

3-1

Image 15
Contents QM30 Series Ice Machines Installation Use and Care, ManualSafety Notices Procedural NoticesThis manual covers the following model numbers Table of Contents This page Intentionally Left Blank Model/Serial Number Location Model Number Section General InformationSection General Information Model/Serial Number LocationOwner Warranty Registration Card Warranty CoverageGeneral Information Section WHO is Covered by this Limited WARRANTY? Residential Warranty CoverageIntentionally Left Blank Section Installation Instructions Section Installation InstructionsLegs Leveling the Ice Machine Installation Instructions SectionLocation of Ice Machine Ice Machine Heat of RejectionElectrical Rating Electrical ServiceVoltage FUSE/CIRCUIT BreakerThis page Intentionally Left Blank Water Supply and Drain Line SIZING/CONNECTIONS Water Service/DrainsWater Supply Drain ConnectionsSv1680b Typical Water Supply and Drain Line Sizing and ConnectionsSequence of Operation Section Ice Machine OperationSection Ice Machine OperationCorrect Ice Bridge Thickness Ice Thickness AdjustmentIce Thickness Adjustment Dial Ice Machine Operation SectionCleaning and Sanitizing Procedure Section MaintenanceSection Maintenance Interior Cleaning and SanitizingRemove the Bin Door Maintenance SectionParts Removal Overview Removing the Water Pump Remove the Water Trough Remove the Overflow TubeRemoving the Overflow Tube C. Remove the Vinyl Hose Remove the Water PumpAmount of Sanitizer ICE Machine Inspection Exterior CleaningCleaning the Condenser Air-Cooled CondenserRemoving the Filter Removal from Service/Winterization Section Before Calling for Service Before Calling for ServiceChecklist To Correct Problem Possible Cause Before Calling for Service SectionPage Manitowoc ICE, INC