Section 3 | Ice Machine Operation |
| Section 3 |
| Ice Machine Operation |
Sequence of Operation
| Ice Making |
| Control Board Relays |
|
| |
| 1 | 2 |
| 3 | Length of | |
| Sequence of | Compressor | Hot Gas Valve |
| Water Pump | |
|
| “ON” Time | ||||
| Operation | Water Fill Valve |
| Fan Motor | ||
|
|
|
| |||
Off | On |
| Off | 2.9 Minutes | ||
1. | Water Purge |
| (175 Seconds) | |||
|
|
|
| |||
2. | Refrigeration | On | On |
| Off | 5 Seconds |
| System |
| ||||
|
|
|
|
|
| |
3. | Freeze Cycle | On | Off |
| On | Automatically |
| determined | |||||
|
|
|
|
|
| |
4. | Harvest Cycle | On | On |
| Off | Automatically |
| determined | |||||
|
|
|
|
|
| |
5. | Auto | Off | Off |
| Off | Until bin thermostat |
| ||||||
|
|
|
|
|
|
1Initial
INITIAL START-UP OR START-UP AFTER AUTOMATIC SHUT-OFF
1. Water Purge
The water fill valve and the hot gas valve are energized for 2.9 minutes (175 seconds). This ensures that the ice making cycle starts with fresh water, and that the refrigerant pressures are equalized prior to refrigeration system
2. Refrigeration System Start-Up
The compressor starts 2.9 minutes (175 seconds) after the water fill valve and hot gas valve are energized. (The water fill valve and hot gas valve remain energized for 5 seconds during compressor
3. Freeze Cycle
The condenser fan motor and water pump are energized and remain on throughout the entire freeze cycle. An even flow of water is directed across the evaporator and into each cube cell, where it freezes.
The control system automatically determines the length of the freeze cycle by monitoring the temperature of the refrigeration system liquid line.
4. Harvest Cycle
The condenser fan motor and water pump de- energize. The water fill valve energizes to purge the water in the water trough. The hot gas valve also energizes at the beginning of the harvest cycle to divert hot refrigerant gas into the evaporator. The hot refrigerant gas warms the evaporator, causing the cubes to slide, as a sheet, off the evaporator and into the ice storage bin.
The control system automatically determines the length of the harvest cycle, based on the temperature of the refrigeration system liquid line at the end of the freeze cycle. At the end of the harvest cycle, the ice machine returns to another freeze cycle (step 3, above).
5. Automatic Shut-Off
The level of ice in the ice storage bin controls the ice machine