Manitowoc Ice QM30 Series specifications Amount of Sanitizer

Page 21

Section 4

Maintenance

Step 7 Mix a solution of cleaner and warm water. Depending on the amount of mineral buildup, a larger quantity of solution may be required. Use the ratio in the table below to mix enough solution to thoroughly clean all parts.

Solution Type

Water

Mixed with

 

 

 

Cleaner

4L. (1 gal)

500 ml (16 oz) cleaner

 

 

 

Step 8 Use ½ of the cleaner/water solution to clean all components. The cleaner solution will foam when it contacts lime scale and mineral deposits; once the foaming stops use a soft bristle brush, sponge or cloth (not a wire brush) to carefully clean the parts. Soak the parts for 5 minutes (15 – 20 minutes for heavily scaled parts). Rinse all components with clean water.

Step 9 While components are soaking, use ½ of the cleaner/water solution to clean all foodzone surfaces of the ice machine and bin. Use a nylon brush or cloth to thoroughly clean the following ice machine areas:

Evaporator plastic parts – including top, bottom and sides

Bin bottom, sides and top

Rinse all areas thoroughly with clean water.

Step 10 Mix a solution of sanitizer and warm water.

Solution Type

Water

Mixed With

 

 

 

Sanitizer

23L. (6 gal)

120ml (4 oz) sanitizer

 

 

 

Step 11 Use 1/2 of the sanitizer/water solution to sanitize all removed components. Use a cloth or sponge to liberally apply the solution to all surfaces of the removed parts or soak the removed parts in the sanitizer/water solution. Do not rinse parts after sanitizing.

Step 12 Use 1/2 of the sanitizer/water solution to sanitize all foodzone surfaces of the ice machine and bin. Use a cloth or sponge to liberally apply the solution. When sanitizing, pay particular attention to the following areas:

Evaporator plastic parts - including top, bottom and sides

Bin bottom, sides and top

Do not rinse the sanitized areas.

Step 13 Replace all removed components.

Step 14 Reapply power and water to the ice machine and place the toggle switch in the WASH position.

Step 15 Add the proper amount of Manitowoc Ice Machine Sanitizer to the water trough.

Model

Amount of Sanitizer

QM30

45 ml (1.5 oz)

Step16 Wait until the sanitize cycle is complete (approximately 45 minutes) then place the toggle switch in the OFF position, disconnect power and water supplies to the ice machine.

4-5

Image 21
Contents QM30 Series Ice Machines Installation Use and Care, ManualSafety Notices Procedural NoticesThis manual covers the following model numbers Table of Contents This page Intentionally Left Blank Section General Information Section General InformationModel/Serial Number Location Model/Serial Number Location Model NumberOwner Warranty Registration Card Warranty CoverageGeneral Information Section WHO is Covered by this Limited WARRANTY? Residential Warranty CoverageIntentionally Left Blank Section Installation Instructions Section Installation InstructionsLegs Location of Ice Machine Installation Instructions SectionIce Machine Heat of Rejection Leveling the Ice MachineVoltage Electrical ServiceFUSE/CIRCUIT Breaker Electrical RatingThis page Intentionally Left Blank Water Supply Water Service/DrainsDrain Connections Water Supply and Drain Line SIZING/CONNECTIONSSv1680b Typical Water Supply and Drain Line Sizing and ConnectionsSection Section Ice Machine OperationIce Machine Operation Sequence of OperationIce Thickness Adjustment Dial Ice Thickness AdjustmentIce Machine Operation Section Correct Ice Bridge ThicknessSection Maintenance Section MaintenanceInterior Cleaning and Sanitizing Cleaning and Sanitizing ProcedureRemove the Bin Door Maintenance SectionParts Removal Overview Removing the Overflow Tube C. Remove the Vinyl Hose Remove the Overflow TubeRemove the Water Pump Removing the Water Pump Remove the Water TroughAmount of Sanitizer ICE Machine Inspection Exterior CleaningCleaning the Condenser Air-Cooled CondenserRemoving the Filter Removal from Service/Winterization Section Before Calling for Service Before Calling for ServiceChecklist To Correct Problem Possible Cause Before Calling for Service SectionPage Manitowoc ICE, INC