Section 2 | Installation Instructions |
Water Service/Drains
WATER SUPPLY
Local water conditions may require treatment of the water to inhibit scale formation, filter sediment, and remove chlorine odor and taste.
Important
If you are installing a Manitowoc water filter system, refer to the Installation Instructions supplied with the filter system for ice making water inlet connections.
Follow these guidelines to install water inlet lines:
•Connect to potable water supply only.
•Do not connect the ice machine to a hot water supply. Be sure all hot water restrictors installed for other equipment are working. (Check valves on sink faucets, dishwashers, etc.)
•If water pressure exceeds the maximum recommended pressure, obtain a water pressure regulator from your Manitowoc distributor.
•Install a water
•Insulate water lines to prevent condensation.
DRAIN CONNECTIONS
Follow these guidelines when installing drain lines to prevent drain water from flowing back into the ice machine and storage bin:
•Drain lines must have a 2.5 cm (1 inch) drop per 1 meter (40 inches) of run, and must not create traps.
•The floor drain must be large enough to accommodate drainage from all drains.
•Insulate the bin drain line to prevent condensation.
WATER SUPPLY AND DRAIN LINE SIZING/CONNECTIONS
CAUTION
Plumbing must conform to state and local codes.
| Water | Water | Ice Machine | Tubing Size Up to Ice | |
| Temperature | Pressure | Connection | Machine Fitting | |
Ice Making | 10°C (50°F) Min.1 | 2.4 bar (35 psi) Min.1 | 3/4” male hose | 0.95 cm (3/8”) | |
minimum inside | |||||
Water Inlet | 30°C (86°F) Max.2 | 6.2 bar (90 psi) Max.2 | connection3 | ||
diameter | |||||
|
|
|
| ||
Ice Making/Bin | 1.59 cm (5/8”) | 1.59 cm (5/8”) | |||
inside diameter | minimum inside | ||||
Water Drain | |||||
|
| flexible hose | diameter | ||
|
|
|
1Min. = Minimum
2Max. = Maximum
3A 3/4” by