Ice Machine Operation | Section 3 |
Ice Thickness Adjustment
ICE BRIDGE SHOULD BE 1.5 MM
TO 3.2 MM THICKNESS
A DIMPLE IN EACH
CUBE CELL IS sv1709
NORMAL
Correct Ice Bridge Thickness
1.Ensure the air filter, front, and back panels are installed properly and close the bin door.
2.During the third harvest cycle open the bin door and catch the entire slab of ice.
3.Weigh the ice slab. The combined weight of all cubes from one harvest should weigh between 200 - 270g (7 -
WARNING
Do not touch electrical wires. Disconnect power to the ice machine before making any ice thickness adjustments.
4.Remove the air filter.
5.Remove the two screws holding the front panel in place and remove the front cover.
6.Locate the ice thickness control dial on the control board (see below). Turn the dial clockwise for a thicker cube or counter clockwise for a thinner cube.
ICE THICKNESS
ADJUSTMENT DIAL
DIAL IS FACTORY
SET TO ZERO
sv1710
Ice Thickness Adjustment Dial
7.Assure all of the panels and air filter are reinstalled properly and the bin door is closed. Repeat steps one through three.
After completing the procedure above, if you are unable to obtain a sheet of ice weighing 200 - 270g (7 -