Maintenance | Section 4 |
Step 4 Wait until water flows over the evaporator (about three minutes) then add the proper amount of Manitowoc Ice Machine Cleaner to the water trough.
Model | Amount of Cleaner |
QM30 | 45 ml (1.5 ounces) |
Step 5 Wait until the clean cycle is complete (approximately 45 minutes) then place the toggle switch in the OFF position, disconnect power and water supplies to the ice machine.
WARNING
Disconnect electric power to the ice machine at the electric switch box before proceeding.
Step 6: Remove parts for cleaning.
A. Remove the Bin Door
•Grasp the rear of the bin door and pull bin door forward approximately 5”.
•Slide bin door to the rear while applying upward pressure (The rear door pins will ride up into the track slot and slide backward to the stop tab).
•While applying pressure against the bin door pull down on the rear of each bin door track until the door pins clear the stop tabs.
•Slide the rear door pins off the end and then below the door track. Slide bin door forward allowing the back of the door to lower into the bin. Continue forward with the bin door until the front pins bottom out in the track.
•Lift right side of door until the front pins clear the track, then remove door from bin.
PRESS DOWN
TO RELEASE
DOOR
STOP TAB
TRACK
SLOT
SLIDE
DOOR
FORWARD