Drying unit (TA) - Maintenance
SF2 in the display: Change the filter
The filter must be changed if SF2 starts
to flash in the display.
To ensure the machine operates
correctly, use original Miele HEPA
filters only (classification 12).
^Press the service panel firmly at both
sides and keep pressing (1) to
release the locking mechanism.
^Place a finger into each of the
openings below the service panel (2)
and push up the locking mechanism.
^Pull the service panel forwards to
open it.
^Remove the filter from its holder, and
replace with a new one.
^Lift the service panel upwards and
push until it clicks shut.
Reset the filter operating hours
counter after changing the filter.
See "Programmable functions" for
how to do this.
Maintenance
57