Please refer to the installation
diagrams supplied with the
machine.
,Furniture and fittings installed
near the machine must be of a
commercial standard able to
withstand the effects of steam and
condensation.
The machine must be installed correctly
and levelled.
Any unevenness in the floor level can
be compensated for and the height of
the machine raised or lowered by
adjusting the front screw feet.
The machine can be installed in the
following ways:
– Free-standing.
The machine can be installed next to
other machines or furniture, or in a
suitable niche. The niche must be at
least 60 cm wide and 60 cm deep.
Built under:
The machine can be installed under
a continuous worktop or sink drainer.
The recess must be at least 60 cm
wide, 60 cm deep and 82 cm high.

Building the machine under a

continuous worktop

The machine lid must be removed as
follows:
^Open the door.
^Undo the fixing screws on the left
and right hand sides.
^Pull the machine lid approx. 5 mm
forwards, lift it upwards and remove
it.
Machines with steam condensers:
To prevent steam damage to the
worktop, the self-adhesive protective
foil supplied (25 x 58 cm) must be
stuck in place underneath the
worktop near the steam condenser.
Installation