Dispensing liquid cleaning agent via DOS 1
Setting the dosage concentration
The dosage concentration must be set exclusively for liquid cleaning agent.
Set it according to the manufacturer's recommendations or the official
standards required.
The dosage concentration must not be altered even if powder cleaning agent
is dispensed via the dispenser in the door.
Step Display / Result
^Press 0until E02 appears. E02
^Turn the programme selector to B.
without DOS Module connected:
with DOS Module connected:
10 = 10 sec dosage duration
1.00 = 1.0 % dosage concentration
^Press ßas many times as necessary
or hold pressed in until the required
value appears in the display, e.g. 0.50.
0.50
The dosage duration/concentration
level has now been set.
Dosage concentration set:
Venting the dispensing system
The dispensing system must be vented:
– when the dosage concentration is set for the first time,
– if the liquid cleaning agent container runs out and is not refilled in time.
Step Display/ Result
^Press 0until E02 appears. E02
^Turn the programme selector to A.d§1
^Press ß.The dispensing system will be vented
automatically. 0will appear in the
display when the venting process has
finished.
^Exit from programming mode.
Then start the Pre-rinse Dprogramme.
Any agents which are in the wash
cabinet after the venting process will
be diluted before being drained away.