Dispensing neutralising agent via DOS 3
Setting the dosage concentration
The dosage concentration for the neutralising agent must be set according to
the manufacturer's recommenedations or the official standards required.
Step Display / Result
^Press 0until E02 appears. E02
^Turn the programme selector to F. The dosage concentration which
has been programmed in will
appear in the display, e.g. 0.10 =
0.10 %
^Press ßas many times as necessary or
hold pressed in until the required value
appears in the display, e.g. 0.2.
0.20
The dosage concentration level has
now been set.
Dosage concentration set:
Venting the dispensing system
The dispensing system must be vented:
– when the dosage concentration is used for the first time,
– if the chemical agent container runs out and is not refilled in time.
Step Display / Result
^Press 0until E02 appears. E02
^Turn the programme selector to E.d§3
^Press ß.The dispensing system will be
vented automatically. 0will appear
in the display when the venting
process has finished.
^Exit from programming mode.
Then start the Pre-rinse Dprogramme.
Any agents which are in the wash
cabinet after the venting process
will be diluted before being drained
away.
Programmable functions