Cancelling a programme

,Where a programme is
cancelled, the items must be
reprocessed.
Programme cancellation due to a
fault
If the programme is cancelled before
completion, a fault message "F.." will
appear in the display.
Depending on the cause, the
appropriate measures must be taken to
resolve the problem. Proceed as
described in "Problem solving guide".
Cancelling the programme manually
Once a programme is running, it should
only be cancelled in extreme cases,
e.g. when articles in the machine rattle
or jostle against each other or the
wrong programme has been selected.
Application: Medical equipment
When testing to EN ISO 15883-1 or
HTM 2030 standards, a programme
must not be interrupted or
cancelled.
,With officially registered
epidemics, any contaminated water
must be decontaminated using a
disinfecting agent before it is
discharged into the sewerage
system.
^Turn the programme selector to f.
The programme will be cancelled after
approx. 2 seconds.
^Open the door a.
,Caution. Water and items in the
machine may be hot. Danger of
burning or scalding.
^Arrange the load securely.(Wear
protective gloves where necessary,
and observe appropriate health and
safety regulations relating to
infectious diseases).
^Replenish powder cleaning agent if
necessary.
^Close the door.
^Start the Drain 6programme.
The water will drain away.
^Select and start the programme
again.
The following procedure should be
followed when dealing with official
cases requiring the containing of
epidemics using the SPECIAL
93°C-10’ programme:
^Start the programme again.
The display will show the temperature
holding time required counting
downwards.