TROUBLESHOOTING SECTION

WARNING: Inspection, testing and repair of electrical equipment should only be performed by a qualified service techni- cian. Many of the tests require that the unit have power to it and live electrical components be exposed.

USE EXTREME CAUTION WHEN TESTING THE MACHINE.

 

 

 

 

 

 

Symptom

Possible Cause

Action

 

 

 

 

 

 

 

Dishmachine fills continuously, only when

Faulty fill microswitch.

Replace microswitch.

 

 

the power is on.

 

 

 

 

 

 

 

 

 

 

Cam timer stalled in fill position.

If cam timer is not rotating, check the

 

 

 

 

voltage to the motor. If voltage is correct,

 

 

 

 

replace timer.

 

 

 

 

 

 

 

 

Shorted out ON/FILL switch.

Check the voltage across the switch. If the

 

 

 

 

voltage is incorrect, replace the switch.

 

 

 

 

 

 

 

 

Shorted/defective liquid level control board

Check voltage going to each component

 

 

 

or probe.

and ensure they are wired correctly. If

 

 

 

 

satisfactory, replace the defective part.

 

 

 

 

 

 

 

Dishmachine runs with the door open.

Door switch shorted out/wired incorrectly.

Check the wiring of the door switch, if

 

 

 

 

correct, replace the door switch.

 

 

 

 

 

 

 

 

Faulty wash relay (wash relay welded

Turn machine off, if wash relay doesn't

 

 

 

closed).

release, replace contactor.

 

 

 

 

 

 

 

 

Faulty control relay.

Measure the continuity between terminals #

 

 

 

 

6 and #9. If there is no continuity, replace

 

 

 

 

the relay.

 

 

 

 

 

 

 

Low wash water pressure.

Water level is too low.

Check to ensure that the drain stopper is in

 

 

 

 

and has an O-ring. Check to ensure that the

 

 

 

 

LLC board and probe are functioning

 

 

 

 

properly.

 

 

 

 

 

 

 

 

Pump intake strainer is clogged.

Remove and clean strainer.

 

 

 

 

 

 

13

Image 15
Contents Technical Manual Table of Contents Specifications of the Tempstar TGP Page GAS Connection Operation Instructions Overview of Operation Overview of Operation Thermostat Adjustment Procedure Auto Calibration AUTO-CALIBRATION ProcedureElectronics Control Board ECB Testing and Setting the Set Point TemperatureTo test the temperature at the T-in Thermistor Testing the ThermistorsGreen LED is off Control Board LED Light IndicationsSymptom Possible Cause Action Troubleshooting SectionMeasure the continuity between terminals # Leaks do not USE Flame Low rinse temperature/low wash Low inlet water temperature DSI Polarity will Damage the Circuit BoardsPiston. If less than 2.0 VDC, replace Control board Remove burner manifold and check correct Letter DIM DimensionsOpening Letter DIM in DIM CM Table DimensionsShown Not Shown Main AssemblyQTY Description MFG no Control BOX Assembly Front ViewControl BOX Assembly TOP View Hood Assembly Cantilever ARM Assembly TUB Assembly Back of TUB, & Drain Assembly Lower Assembly Right Side Incoming Plumbing Assembly Incoming Plumbing Parts Lists GAS Pack Assembly Upper WASH, & Rinse ARM Assembly Lower WASH, & Rinse ARM Assembly Steam Coil Assembly Steam Coil Assembly Parts Lists Are not Included with This Assembly Not Shown Rinse Tank AssemblyRED Green LED Electronic Control Drawer ComponentsMetric Conversions Electrical Diagram