Jackson technical manual Specifications of the Tempstar TGP

Page 3

SPECIFICATIONS OF THE TEMPSTAR TGP

PERFORMANCE/CAPABILITIES

 

VOLTS

PHASE

AMPS

OPERATING CAPACITY (RACKS/HOUR)

 

208 - 240

1

6.7

RACKS PER HOUR

57

 

 

 

DISHES PER HOUR

1425

WATER REQUIREMENTS

 

GLASSES PER HOUR

1425

INLET TEMPERATURE

 

70 -140°F

 

 

INLET TEMPERATURE

 

21.11-60°C

OPERATING CYCLE (SECONDS)

 

GALLONS PER HOUR

 

52.0

WASH TIME

45

LITERS PER HOUR

 

196.84

RINSE TIME

11

WATER LINE SIZE I.P.S. (Minimum)

3/4”

DWELL TIME

2

WATER LINE SIZE I.P.S. (Minimum)

1.9 CM

TOTAL CYCLE TIME

60

DRAIN LINE SIZE I.P.S. (Minimum)

1-1/2”

 

 

DRAIN LINE SIZE I.P.S. (Minimum)

3.81 CM

TANK CAPACITY (GALLONS)

 

FLOW PRESSURE P.S.I. (Optimum)

20

WASH TANK (MINIMUM)

8.0

 

 

 

BOOSTER TANK

3.0

GAS REQUIREMENTS

 

 

 

 

BTU INPUT RATE

 

55,000

TANK CAPACITY (LITERS)

 

INLET LINE PRESSURE (TOWN GAS)

4-6” wci

WASH TANK (MINIMUM)

30.28

MANIFOLD PRESSURE

(MINIMUM)

.25 wci

BOOSTER TANK

11.36

 

(MAXIMUM)

2.3 wci

WASH PUMP CAPACITY

 

FRAME DIMENSIONS

 

 

GALLONS PER MINUTE

150

WIDTH

 

25 3/4”

LITERS PER MINUTE

567.81

WIDTH

 

65.4 CM

 

 

DEPTH

 

25 1/4”

TEMPERATURES

 

DEPTH

 

64.14 CM

WASH ---°F (MINIMUM)

150

HEIGHT

 

56 3/4”

WASH ---°C (MINIMUM)

65.56

HEIGHT

 

144.15 CM

RINSE ---°F

180

STANDARD TABLE HEIGHT

34”

RINSE ---°C

82.22

STANDARD TABLE HEIGHT

86.36 CM

 

 

MAXIMUM INSIDE CLEARANCE

17 1/4”

ELECTRICAL REQUIREMENTS

 

MAXIMUM INSIDE CLEARANCE

43.82 CM

WASH PUMP MOTOR HP

3/4

 

 

 

CIRCULATOR PUMP MOTOR HP

1/12

RACKS

 

 

 

 

DISH 20” X 20” (50.8 CM X 50.8 CM)

OPTIONAL

 

 

GLASS & SILVER 20” X 20” (50.8 CM X 50.8 CM)

OPTIONAL

1

Image 3
Contents Technical Manual Table of Contents Specifications of the Tempstar TGP Page GAS Connection Operation Instructions Overview of Operation Overview of Operation Thermostat Adjustment Procedure Auto Calibration AUTO-CALIBRATION ProcedureElectronics Control Board ECB Testing and Setting the Set Point TemperatureTo test the temperature at the T-in Thermistor Testing the ThermistorsGreen LED is off Control Board LED Light IndicationsSymptom Possible Cause Action Troubleshooting SectionMeasure the continuity between terminals # Leaks do not USE Flame Low rinse temperature/low wash Low inlet water temperature DSI Polarity will Damage the Circuit BoardsPiston. If less than 2.0 VDC, replace Control board Remove burner manifold and check correct Letter DIM DimensionsOpening Letter DIM in DIM CM Table DimensionsShown Not Shown Main AssemblyQTY Description MFG no Control BOX Assembly Front ViewControl BOX Assembly TOP View Hood Assembly Cantilever ARM Assembly TUB Assembly Back of TUB, & Drain Assembly Lower Assembly Right Side Incoming Plumbing Assembly Incoming Plumbing Parts Lists GAS Pack Assembly Upper WASH, & Rinse ARM Assembly Lower WASH, & Rinse ARM Assembly Steam Coil Assembly Steam Coil Assembly Parts Lists Are not Included with This Assembly Not Shown Rinse Tank AssemblyRED Green LED Electronic Control Drawer ComponentsMetric Conversions Electrical Diagram