Jackson Tempstar TGP Electronics Control Board ECB, Testing and Setting the Set Point Temperature

Page 11

ELECTRONICS CONTROL BOARD (ECB)

Testing and Setting the Set Point Temperature

The Control Board regulates the temperature of the water in the heat exchanger system. This water is also used as the rinse water for the rinse cycle of the dishwasher. It does this by regulating the flame of the burner by increasing or decreasing the voltage to the modulating valve. The modulating valve, in turn, increases or decreases the gas pressure going to the burner manifold depending on the voltage it is getting from the control board. From time to time it may be necessary to check or adjust the setting of this water tem- perature. To test the setting or to reset the temperature of the rinse water, make sure the unit is on and the green LED on the board is flashing steadily. Insert the NEGATIVE (Black/Common) probe of a multi-meter set on DC volts in the BLACK test point (see above). Insert the POSITIVE (Red) probe of the multi-meter in the BLUE test point. The reading will indicate the set point temperature. The fac- tory setting is 4.25 VDC which corresponds to 198#F (92#C). Adjustments to the set point are made on the BLUE POTENTIOMETER directly below the BLUE test point. With a very small slotted screwdriver rotate the trim screw on the potentiometer clockwise (CW) to increase the voltage (and Temperature) and counterclockwise to decrease.

9

Image 11
Contents Technical Manual Table of Contents Specifications of the Tempstar TGP Page GAS Connection Operation Instructions Overview of Operation Overview of Operation Thermostat Adjustment Procedure Auto Calibration AUTO-CALIBRATION ProcedureElectronics Control Board ECB Testing and Setting the Set Point TemperatureTo test the temperature at the T-in Thermistor Testing the ThermistorsGreen LED is off Control Board LED Light IndicationsSymptom Possible Cause Action Troubleshooting SectionMeasure the continuity between terminals # Leaks do not USE Flame Low rinse temperature/low wash Low inlet water temperature DSI Polarity will Damage the Circuit BoardsPiston. If less than 2.0 VDC, replace Control board Remove burner manifold and check correct Letter DIM DimensionsOpening Letter DIM in DIM CM Table DimensionsShown Not Shown Main AssemblyQTY Description MFG no Control BOX Assembly Front ViewControl BOX Assembly TOP View Hood Assembly Cantilever ARM Assembly TUB Assembly Back of TUB, & Drain Assembly Lower Assembly Right Side Incoming Plumbing Assembly Incoming Plumbing Parts Lists GAS Pack Assembly Upper WASH, & Rinse ARM Assembly Lower WASH, & Rinse ARM Assembly Steam Coil Assembly Steam Coil Assembly Parts Lists Are not Included with This Assembly Not Shown Rinse Tank AssemblyRED Green LED Electronic Control Drawer ComponentsMetric Conversions Electrical Diagram