Everpure 325 View Surevend Average Calibration Value, Press , then press until the display shows

Page 75
2. CONTINUE.

Cold Drink Center (327/328) Operator’s Guide

On input screen #2, you can press the following letters to perform the indicated operation:

ADispense ice (and turn on the icemaker compressor if the hop- per is not full)

BForce CO2 valve on

CDispense carbonated water

DDispense still water

5.Actuate each switch or sensor to test its function. As you actuate each input, the display element representing that switch blinks on. Releasing the switch causes that element to blink off again.

6.CONTINUE.

VIEW SUREVEND™ AVERAGE CALIBRATION VALUE

1. Press , then press until the display shows.

2. CONTINUE.

 

CAL.AVEXXX

 

 

 

3280020

Page 69

August, 2003

XXX represents the average sensor calibration value (should be between 50 and 255 for proper sensor operation - i.e. 51 through 254). Although this number could go as low as 20, the SureVend™ system will be inoperative in this condition.

VIEW SUREVEND™ LAST RECORDED CALIBRATION VALUE

1. Press , then press until the display shows.

XXX can be any number from 0 to 255, and represents theCALmost.LSTrecentXXX value read from the sensor. The lower the number, the greater the sensor

blockage. A number of 255 means that there is a fatal problem with the SureVend™ interface board. Ensure the SureVend™ interface PCB is properly connected to the main controller PCB.

Image 75
Contents Page Crane Merchandising Systems Parts and Support Table of Contents Factory Default Throw Times and Volumes View Diagnostic Messages Page Water Pressure Power RequirementsWater Requirements Country Volts Frequency Hz Current AmpsPositioning The Merchandiser Final InstallationSupply Line Requirements Flushing Water Supply LineLoad the coin Mechanism Open the cab- inet doorMonetarySCREW door Install Options Everpure Water Filter Installation Hydrolife Filter Installation Load the cup mechanism Get The Machine Ready To Vend DrinksBag-in-box machines Syrup tank machinesObserve Proper Hygiene do not Touch the Cups Set up the CO2 tank Cold Drink Center 327/328 Operator’s Guide Handle as shown. Once BrixAdjustments and Minor Maintenance Refills Press Water pump starts, and the display showsLimit Screw see Warning Adjusting Screw Priming Switch Adjusting Screw Lock Set the Main Switch to the on up position Press Then Getting Around Programming The Cold Drink CenterDisplays Function KeysOther Keys Some Conventions Helpful HintControl Panel Switch Functions Explained Message if desired see Edit Custom Message on SureVendOr after being downloaded into a Enter a NEW Supervisor Code Gain Access to the Supervisor ModeSupervisor Mode Only Follow the steps in Gain Access To The Supervisor Mode onEnter a NEW Data Recall Code UsageExamples Press Consult your DEX supplier before choosing this option SET Talker ModeSET Printer or DEX Mode To turn the talker option on or OFFSET DEX Options Printer mode onlyMechanism choice Select Display LanguageList of bills. See Initial Setup Of NonStandard Bill Valida Select Bill Validator and OptionsTor on Options on page 28 , to select Initial Setup of Nonstandard Bill ValidatorSelect Monetary Options Select Card Reader and OptionsSome examples Example If setting isExample SET UP Winner Mode Selections. Press SET UP MUG DiscountDisable Selections in the Merchandiser This display means that all regular size selections a F areThis will reload the fac SET UP CUP SizesDisplay momentarily shows This will reassignFor the selection Pressing SET UP a DrinkAppear View and change the settings for syrup View and change the settings for ice throw timeSyrup Throw Still and Carb Ice Extra Ice Factory Default Throw Times and VolumesCup Size Volume Time Sec Special SelectionsPress Until something like Displays. Press Blended DrinksSelect To use. For example, set percentage plus to This meansPress To select the type of pumps in your machine Configure Pump TypeSpritz Drinks SetSET UP Automatic Delivery Door Options Configure Number of SelectionsAbcdef Assign CUP Sizes to Selections Supervisor Mode OnlyOptional or Mandatory Surevend Turn Surevend on or OFFXxxxxx represents the current software version number SET UP the Surevend ANTI-JACKPOT TimerView Software Version Receives changeSET the Time of DAY SET MONTH, DATE, and YearSET Daylight Savings Time Options SET TIME-OF-DAY Inhibit Vending SET TIME-OF-DAY Free VendingSET TIME-OF-DAY Discount Vending XX is the currently set start Time Interval EditingPress the number of the time interval you This display tells you whetherNow shows Stop press X.XX===Display the factory-set message, press Select AN OUT-OF-SERVICE MessageSelect a Standby Message Machine Press Then pressCharacter is displayed Select a Freevend MessageEnd Of Message Character ShortcutDrink 0. Press To view the rest of the available selections View Machine Configuration SettingSetting Press Automatic vend doorPress To view the rest of the available selections View CUP Sizes Assigned to SelectionsPayout Coins Press Then press Until the display shows something likeView Nonresettable Sales and Vend Data SET PricesPress Display shows XX.XX is a dollar and cents View Total Sales by Selection Both CUP Sizes View Data Four Different WaysView Total Paid Sales View Total Sales by Drink SizeView Total Sales by Individual Selection View Total Paid Sales by Price LineTo view the total sales of each large cup selection Clear ALL Resettable Data Clear Paid Sales Data onlyView Amount in Coin BOX Not Shown if Zero View Amount in Validator Not Shown If ZeroView Freevend Sales by Time Interval View Discount Sales by Time Interval View Free Vends Not Shown If ZeroView Winners Not Shown If Zero View Time Data 1100 am View Total Unpaid SalesView Total Unpaid Vends At 942 amGain Access To The Supervisor Mode on View Number of Test VendsView Machine ID Number View Number of CUP Ring Cycle Failures View Home Switch USE Related to SurevendCycled. Check the cup ring adjustment see Cup mechanism View CUP Ring Cycles Related to SurevendDisplay shows You may now test vend Vend modeTest Vend Selections and Verify Credit Added Test the DisplayTest Throw Carbonated Water Test Drop a CUPTest the Automatic Delivery Door Test Throw Still WaterTest the ICE Maker Test the Syrup Pumps Test the Carbonator At this Pail and dump its contents. The display will showFill during the Coolsan process Read With the time message transposedTest Various Switches and Sensors Input Screen 1 DefinitionsInput Screen 2 Definitions Press , then press until the display shows View Surevend Average Calibration ValueThen press Until the display shows View Diagnostic MessagesDisplay shows FINISHED. Reconfigure the merchandiser Settings price, time, monetary options, messages, etcError is corrected. Check for bill stuck in the acceptance Keyswitch input is active and configured as an inhibitRect config number directly on this screen without further Power OFF and then onDownload Data to a Pdcd SET Freevend Options Cold Drink Center 327/328 Operator’s Guide Index Page Polarity Check Supervisor Total Sales by Selection View Terms and Conditions of Sale