Miele DA 6480, DA 6490, DAG 500, DAG 1000 Grease filters, Special instructions for control buttons

Page 13

Cleaning and Care

Special instructions for control buttons

The controls may change or become discolored if not cleaned regularly, clean soiled areas immediately.

Do not use a stainless steel cleaner on the controls.

￿Press the On/Off button on the top of the ventilation system.

The vent will rise.

The fan will start at power level 2.

￿Press and hold the 0/1 button until the fan turns off.

Grease filters

The reusable metal grease filters remove solid particles from the vented kitchen air (grease, dust, etc). This helps keep the ventilation system clean.

The grease filters should be cleaned every 3 - 4 weeks, otherwise cleaning will become more difficult.

￿A dirty filter is a fire hazard.

￿At the upper edge, push the grease filter down until you can pull it forward, then up and out.

Hold the filter securely to prevent it from falling and damaging the cooktop.

The ventilation system cannot be operated when the filters are removed.

13

Image 13
Contents En US, CA Contents Important Safety Instructions To Reduce the Risk of a Cooktop Grease Fire UseEvacuate and Call the Fire Department Installation With the internal DAG 500 exhaust blower Not included Functional descriptionWith the DAG 1000 external blower Not included Description of the appliance Delayed shut down feature Temperature warning light Power level settingsVent collar Delayed shut-off feature Selecting the power level Operation Raising the vent / Turning on the fanTemperature warning § Cleaning the casing Cleaning and CareStainless steel Special instructions for control buttons Grease filtersCleaning the grease filters Repairs After Sales ServicePage Installation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Appliance dimensions Exhaust duct connection diameters Cabinet dimensions Appliance dimensions Installation using the DAG 500 internal blower Appliance dimensions Installation preparation InstallationInstallation Installing the DAG 500 blower box on the front Venting direction towards the rear Mount the vent collar on the rear Installing the DAG 500 blower box on the rear Preparing the electrical connection Installation Installation with the DAG 1000 external blower Air extraction Only for Canada with the DAG 500 Internal blower Condensate trapThis Appliance Must be Grounded Electrical connectionElectrical connection if using an external blower Page Alteration rights reserved Nr 045 140