Installation
Installation with the DAG 1000 external blower
If using DAG 1000 external blower, a connection plate much be installed on the ventilation system instead of the blower box.
It can be mounted on either on the front or the rear of the appliance.
If the connection plate is mounted on the front, the exhaust can only be vented to the front.
If the connection plate is mounted on the rear, the exhaust can only be vented to the rear.
Plug the connector for the blower into the socket in the housing as shown.
The connection plate is installed the same way as described for the blower box.
The cover is installed on the housing on the opposite side of the connection plate.
The ventilation system is connected to the external blower by an additional control cable. Please follow the Operating and Installation Instructions for the DAG 1000.
The control cable will be connected in the terminal box of the ventilation system (see "Electrical connection").
The ventilation system and the external blower are connected by a 10" (254 mm) vent duct.
34