Miele DA 6490, DA 6480, DAG 1000 Installing the DAG 500 blower box on the front

Page 28

Installation

￿Remove the screws from the countertop.

￿Lift the appliance back out of the cabinet.

￿Pre-drill the marked mounting holes on the cabinet floor.

￿Tighten the mounting brackets on the appliance at the marked position.

￿Lay the vent housing on the floor on a blanket or other suitable protection in order to mount the DAG 500 blower or DAG 1000 blower adapter.

Decide on the venting direction.

If the ventilation system is installed in a cabinet, the vent duct can go through the floor, the right or left side, or to the rear of the cabinet.

Installing the DAG 500 blower box on the front

Venting to the side or downwards:

￿Plug the connection cable from the ventilation system into the blower motor.

￿Turn the blower box so that the vent collar faces in the desired direction – left, right or downwards.

￿Mount the blower box to the housing with 4 screws.

28

Image 28
Contents En US, CA Contents Important Safety Instructions Use To Reduce the Risk of a Cooktop Grease FireEvacuate and Call the Fire Department Installation With the internal DAG 500 exhaust blower Not included Functional descriptionWith the DAG 1000 external blower Not included Description of the appliance Delayed shut down feature Temperature warning light Power level settingsVent collar Selecting the power level Delayed shut-off featureOperation Raising the vent / Turning on the fanTemperature warning § Cleaning the casing Cleaning and CareStainless steel Grease filters Special instructions for control buttonsCleaning the grease filters After Sales Service RepairsPage Installation Instructions Page Disposal of packing material Caring for the environmentDisposal of an old appliance Appliance dimensions Exhaust duct connection diameters Cabinet dimensions Appliance dimensions Installation using the DAG 500 internal blower Appliance dimensions Installation Installation preparationInstallation Installing the DAG 500 blower box on the front Venting direction towards the rear Mount the vent collar on the rear Installing the DAG 500 blower box on the rear Preparing the electrical connection Installation Installation with the DAG 1000 external blower Air extraction Condensate trap Only for Canada with the DAG 500 Internal blowerElectrical connection This Appliance Must be GroundedElectrical connection if using an external blower Page Alteration rights reserved Nr 045 140