Miele DA 337 I Special installation instructions, Installing in a 27 9/16 70 cm wide cabinet

Page 35

Installation

Special installation instructions

Installation in to a cabinet with 19 mm thick walls

The runners have to be adapted as shown above.

Screw the runners to the cabinet with the "19 mm" marking facing upwards as shown above.

Installing in a 27 9/16” (70 cm) wide cabinet:

The runners are secured to the spacer blocks.

Screw the spacer block to the cabinet with the lower edge flush with the bottom of the cabinet using the 4.0 x 16 mm screws. The first row of screws must be aligned with the pencil marks.

Screw the runners to the spacer block using the 3.5 x 9.5 mm self tap- ping screws.

35

Image 35
Contents Operating Instructions For the DA 337 i Ventilation System Contents Disposal of an old appliance Caring for the environmentDisposal of packing material Save These Instructions and Review Them Periodically To Reduce the Risk of a Range TOP Grease Fire To reduce the risk of fire, use only metal ductworkUse an extinguisher only if Be careful to prevent burnsDisposal of old appliances Guide to the appliance Active charcoal filter button Delayed Shut Down buttonGrease filter button By air recirculaton Description of the functionsBy air extraction Turning on the exhaust fan Selecting the power levelOperation Turning the lights on or off Safety shut off featureTurning off the exhaust fan Reading the filter timer Grease filter timerActive Charcoal Filter timer Changing the hours preset in the grease filter timer Changing the filter timerActive charcoal filter Grease filters Cleaning and careHousing Internal filter External filterReturn the filters Inserting / replacing the active charcoal filter Changing the light bulb After Sales Service Appliance dimensions Appliance dimensions Metric conversion table Cabinet back panelPage Installation accessories InstallationSpacer blocks Reducing collarNon-return flap RunnersAir extraction with integrated fan Installation procedureRecirculation mode Non-return flapAir extraction Reducing collarRunners Fit the runners Hang the cabinet doorAlign the height of the appliance Position the appliance in the cabinet Fit side spacers at the sides of the appliance Align the depth of the applianceInstallation Connection Set up for recirculation mode connectionElectrical connection Installing in a 27 9/16 70 cm wide cabinet Special installation instructionsInstallation in to a cabinet with 19 mm thick walls Installation Exhaust ducting and connections Air extractionAir extraction Electrical connection Technical data Page Page