Miele DA 337 I operating instructions Technical data

Page 40

Technical data

Maximum load . . . . . . . . . . . . . 450 W

Lighting . . . . . . . . . . . . . . . . 2 x 50 W

Voltage . . . . . . . . . . . . . . . . . 120 VAC

Frequency . . . . . . . . . . . . . . . ~ 60 Hz

Circuit breaker . . . . . . . . . . . . . . . 15 A

Fan

Values derived using 6” (150 mm) duct- ing and EN 61591 test procedures

Level I. . . . . . . . . . . 190 cfm (320 m3/h) Level II . . . . . . . . . . 295 cfm (500 m3/h) Level III. . . . . . . . . . 420 cfm (710 m3/h) Intensive level. . . . . 495 cfm (840 m3/h)

Unrestricted . . . . . . 540 cfm (920 m3/h)

Recirculation mode with active char- coal filter:

Level I. . . . . . . . . . . 165 cfm (280 m3/h) Level II . . . . . . . . . . 250 cfm (430 m3/h) Level III. . . . . . . . . . 350 cfm (600 m3/h) Intensive level. . . . . 400 cfm (680 m3/h)

Miele Active Charcoal Filter DKF 8, Art.Nr. 28.9961.34

40

Image 40
Contents Operating Instructions For the DA 337 i Ventilation System Contents Disposal of packing material Caring for the environmentDisposal of an old appliance Save These Instructions and Review Them Periodically To reduce the risk of fire, use only metal ductwork To Reduce the Risk of a Range TOP Grease FireBe careful to prevent burns Use an extinguisher only ifDisposal of old appliances Guide to the appliance Grease filter button Delayed Shut Down buttonActive charcoal filter button By air extraction Description of the functionsBy air recirculaton Operation Selecting the power levelTurning on the exhaust fan Turning off the exhaust fan Safety shut off featureTurning the lights on or off Active Charcoal Filter timer Grease filter timerReading the filter timer Changing the filter timer Changing the hours preset in the grease filter timerActive charcoal filter Housing Cleaning and careGrease filters External filter Internal filterReturn the filters Inserting / replacing the active charcoal filter Changing the light bulb After Sales Service Appliance dimensions Appliance dimensions Cabinet back panel Metric conversion tablePage Installation Installation accessoriesReducing collar Non-return flapRunners Spacer blocksInstallation procedure Recirculation modeNon-return flap Air extraction with integrated fanRunners Reducing collarAir extraction Hang the cabinet door Fit the runnersPosition the appliance in the cabinet Align the height of the applianceAlign the depth of the appliance Fit side spacers at the sides of the applianceInstallation Electrical connection Set up for recirculation mode connectionConnection Installation in to a cabinet with 19 mm thick walls Special installation instructionsInstalling in a 27 9/16 70 cm wide cabinet Installation Air extraction Exhaust ducting and connectionsAir extraction Electrical connection Technical data Page Page