Electrical connection

Electrical connection

All electrical work should only be per- formed by a qualified electrician in ac- cordance with national and local safety regulations.

The hood comes equipped with a

5 ft (1,5 m) power cord for connection to a 120 VAC, 15 A, 60 Hz power out- let.

Verify that the information on the data plate matches the household electrical supply before installing the hood. The data plate is visible once the grease fil- ter has been removed.

Important

CAUTION:

Ensure that power supply is OFF during installation.

If you have any questions as to how to connect this hood to your build- ing power supply, please call Miele or consult a licensed electrician.

WARNING

THIS APPLIANCE MUST BE

GROUNDED

39

Image 39
Contents Operating Instructions For the DA 337 i Ventilation System Contents Caring for the environment Disposal of packing materialDisposal of an old appliance Save These Instructions and Review Them Periodically To Reduce the Risk of a Range TOP Grease Fire To reduce the risk of fire, use only metal ductworkUse an extinguisher only if Be careful to prevent burnsDisposal of old appliances Guide to the appliance Delayed Shut Down button Grease filter buttonActive charcoal filter button Description of the functions By air extractionBy air recirculaton Selecting the power level OperationTurning on the exhaust fan Safety shut off feature Turning off the exhaust fanTurning the lights on or off Grease filter timer Active Charcoal Filter timerReading the filter timer Changing the hours preset in the grease filter timer Changing the filter timerActive charcoal filter Cleaning and care HousingGrease filters Internal filter External filterReturn the filters Inserting / replacing the active charcoal filter Changing the light bulb After Sales Service Appliance dimensions Appliance dimensions Metric conversion table Cabinet back panelPage Installation accessories InstallationSpacer blocks Reducing collarNon-return flap RunnersAir extraction with integrated fan Installation procedureRecirculation mode Non-return flapReducing collar RunnersAir extraction Fit the runners Hang the cabinet doorAlign the height of the appliance Position the appliance in the cabinetFit side spacers at the sides of the appliance Align the depth of the applianceInstallation Set up for recirculation mode connection Electrical connectionConnection Special installation instructions Installation in to a cabinet with 19 mm thick wallsInstalling in a 27 9/16 70 cm wide cabinet Installation Exhaust ducting and connections Air extractionAir extraction Electrical connection Technical data Page Page