Scotsman Ice SCCG30, SCCP30 service manual Specifications

Page 2

SCCG30 & SCCP30

Service Manual

Specifications

This ice machine is designed to be used indoors, in a controlled environment. It can be used in a wide variety of environmental conditions, but there are limits. Use outside of the listed limitations is misuse and will void the warranty.

Air temperature limits:

The ice machine will operate adequately within the limits, but functions best in temperatures between 70 and 80 degrees F.

Minimum – 50 degrees F. (10oC)

Maximum – 100 degrees F. (38oC)

Water temperature limits:

Minimum – 40 degrees F. (4.5oC)

Maximum – 100 degrees F. (38oC)

Water pressure limits:

Options:

Door Panel kits:

Finished door panels are available from Scotsman for attachment to the machine, or a custom panel can be made.

Kit Number

Panel Finish

Handle Finish

KDFS

Stainless Steel

Stainless Steel

Drain Conversion:

A gravity drain model can be converted to a drain pump model by installing a drain pump kit. The drain pump kit consists of a drain pump, wiring harness and associated tubing. The kit number is A39462-021.

Warranty Information

Minimum – 20 psi (1.4 bar)

Maximum – 80 psi (5.5 bar)

Because the ice machine is making a food product, the water supply to the ice machine must be potable, or fit for human consumption.

Warranty information is supplied separately from this manual. Refer to it for coverage. In general, the warranty covers defects in materials or workmanship and does not cover corrections of installation errors or maintenance.

Electrical

115 volt, 60 Hz. Plug into dedicated 15 amp circuit.

Power consumption: 400-180 Watts. Varies during Freeze and Harvest cycles.

Voltage limits:

Minimum - 104 volts

Maximum – 126 volts

Models: There are six models, all air cooled:

SCCPA30M-1SU – Pump model, stainless cabinet

SCCGA30M-1SU – Gravity drain model, stainless cabinet

September 2009

Page 2

Image 2
Contents Table of Contents IntroductionSpecifications LEG Adjustment Places Drain Flexible Tubing Cabinet LayoutAir flow Filters and Treatment Installation OverviewWater Quality Door Covering Door Panel Custom PanelDoor Panel Attachment Custom Panel Installation Notes Door swing changeInstallation Water & Drain Drain Pump Model drain installationGravity Drain Initial Start Up Installation check listElectrical & Start Up Cube Size Adjustment Side Views of CubesHarvest Time Adjustment Use How to clean the condenser and winterize Condenser cleaningHow to remove scale from the ice making system Electrical Components System InformationOverall Water System Components Performance Information Refrigeration System Service Diagnosis Problem Likely Cause Probable SolutionMakes excessive noise Removal and Repair Harvest Timer Cube Size ThermostatRemoval and Repair Cabinet Removal SCCG30 & SCCP30 Refrigeration Service