Scotsman Ice SCCP30, SCCG30 service manual Door swing change, Installation Notes

Page 9

SCCG30 & SCCP30 Service Manual

Door swing change

The door can be attached to open with hinges on the left or right using new brackets shipped loose in the ice bin. Retain all screws for re-use.

To change:

1.Remove innermost screw holding each hinge to cabinet, loosen the other.

2.Slide hinges to the side and remove door from cabinet. Remove screws loosened in step

1 from both hinge brackets.

3.Remove two screws securing top panel to back, pull top panel back and remove from cabinet.

8.Remove the upper hinge and move it to the door's opposite side, bottom location. Secure using the original screws.

9.Remove the original lower hinge and move it to the door's opposite side, upper location. Secure using the original screws.

10.Install a screw removed in step 2 in outermost hole of upper and lower cross braces.

11.Attach the door to the cabinet using the original screws.

12.Return kickplate and front service panel to their original positions and attach to the cabinet using the original screws.

Installation Notes

4.Remove two screws at the top and lift the door hinge bracket out of the cabinet. Replace with the one supplied loose with the machine. Fasten it to the cabinet using the original screws.

Door Hinge Bracket

Built In Situations: If a finished floor is to be installed in the area after the ice machine has been built in, shims the expected thickness of the floor should be installed under the unit to keep the machine level with the planned floor level.

Installations on a slab: Use a pump model and pump the water to the point of drainage. Pump models will pump 1 story (10 feet) high.

5.Return the top panel to the cabinet and fasten it with the original screws.

6.Remove kickplate and front service panel.

7.Remove two front screws and two bottom screws holding the bottom cross brace to the cabinet. Replace the brace with the one supplied loose with the machine. Secure it using the original screws.

Installations over a crawl space or basement: Either gravity drain or pump model units may be used, if there is not enough room behind the machine for a drain/waste receptacle, the drain will have to be below the floor.

Note: When installed in a corner, the door swing may be limited due to handle contact with the wall or cabinet face.

Screw Below

September 2009

Page 9

Image 9
Contents Introduction Table of ContentsSpecifications Cabinet Layout LEG Adjustment Places Drain Flexible TubingAir flow Installation Overview Water QualityFilters and Treatment Door Panel Custom Panel Door CoveringDoor Panel Attachment Custom Panel Door swing change Installation NotesDrain Pump Model drain installation Installation Water & DrainGravity Drain Installation check list Electrical & Start UpInitial Start Up Side Views of Cubes Cube Size AdjustmentHarvest Time Adjustment Use Condenser cleaning How to clean the condenser and winterizeHow to remove scale from the ice making system System Information OverallElectrical Components Water System Components Performance Information Refrigeration System Problem Likely Cause Probable Solution Service DiagnosisMakes excessive noise Removal and Repair Cube Size Thermostat Harvest TimerRemoval and Repair Cabinet Removal SCCG30 & SCCP30 Refrigeration Service