Bin Thermostat

9.

Reverse to reassemble.

1.

Disconnect electrical power.

 

Curtain

 

 

 

 

 

 

1.

Shut unit off.

 

 

 

 

 

 

 

 

 

 

 

 

2.

Loosen both thumbscrews holding curtain

 

 

 

 

Electrical Shock

 

 

 

 

 

 

 

bracket to freezing chamber.

 

 

 

 

Hazard.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Disconnect electrical

 

 

 

 

 

 

 

 

power before

 

3.

Pull out and remove curtain with bracket from ice

 

 

 

 

beginning removal

 

 

machine.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Remove service panel.

4.

Reverse to reassemble.

3.

Remove back panel.

 

Spray Platform

 

 

 

 

 

 

1.

Remove curtain.

Note: If unit is built in it must be pulled out to

 

 

 

change the bin thermostat.

2.

Lift spray platform up until it disconnects from its

 

 

 

 

 

 

 

 

 

 

 

 

4.

Pull cap tube out from the back of the ice

 

fitting.

 

 

 

storage bin and cap tube holder.

3.

Pull forward and remove from the ice machine.

 

 

 

 

 

 

5.

Remove two screws and the bin thermostat

4.

Reverse to reassemble.

contact section from its mounting bracket.

 

 

 

6.

Disconnect two wires from the bin thermostat

 

Water Pump

 

 

 

contact section and remove the thermostat from

1.

Disconnect electrical power.

the ice machine.

 

 

 

7.

Reverse to reinstall.

2.

Remove spray platform

 

 

 

Inlet Water Solenoid Valve

3.

Remove back panel.

 

 

 

 

 

 

 

 

 

 

 

1.

Disconnect electrical power.

 

Note: If unit is built in it must be pulled out to

 

change the water pump.

 

 

 

 

 

 

 

2.

Remove service panel.

 

 

 

 

 

 

 

 

 

 

 

 

4.

Disconnect power and ground wires from pump

3.

Shut water supply OFF.

 

motor.

4.

Disconnect inlet water supply tube from inlet

5.

Rotate pump body CW and lift up to remove it.

water solenoid valve.

 

 

 

 

 

 

 

 

 

6.

Reverse to reassemble.

5.Unplug wire harness from valve coil.

6.Remove two screws holding valve to chassis.

7.Squeeze hose clamp larger and push away from solenoid valve outlet.

8.Pull hose from outlet of valve.

September 2009

Page 25

Image 25
Contents Introduction Table of ContentsSpecifications Cabinet Layout LEG Adjustment Places Drain Flexible TubingAir flow Water Quality Installation OverviewFilters and Treatment Door Panel Custom Panel Door CoveringDoor Panel Attachment Custom Panel Door swing change Installation NotesDrain Pump Model drain installation Installation Water & DrainGravity Drain Electrical & Start Up Installation check listInitial Start Up Side Views of Cubes Cube Size AdjustmentHarvest Time Adjustment Use Condenser cleaning How to clean the condenser and winterizeHow to remove scale from the ice making system Overall System InformationElectrical Components Water System Components Performance Information Refrigeration System Problem Likely Cause Probable Solution Service DiagnosisMakes excessive noise Removal and Repair Cube Size Thermostat Harvest TimerRemoval and Repair Cabinet Removal SCCG30 & SCCP30 Refrigeration Service