SCCG30 & SCCP30
Service Manual
Removal and Repair
Bin Thermostat | 9. | Reverse to reassemble. | |||||||
1. | Disconnect electrical power. |
| Curtain | ||||||
|
|
|
|
|
| 1. | Shut unit off. | ||
|
|
|
|
|
| ||||
|
|
|
|
|
| 2. | Loosen both thumbscrews holding curtain | ||
|
|
|
| Electrical Shock |
| ||||
|
|
|
|
|
| bracket to freezing chamber. | |||
|
|
|
| Hazard. |
|
| |||
|
|
|
|
|
|
|
| ||
|
|
|
| Disconnect electrical |
|
|
|
| |
|
|
|
| power before |
| 3. | Pull out and remove curtain with bracket from ice | ||
|
|
|
| beginning removal |
|
| machine. | ||
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| |||
2. | Remove service panel. | 4. | Reverse to reassemble. | ||||||
3. | Remove back panel. |
| Spray Platform | ||||||
|
|
|
|
|
| 1. | Remove curtain. | ||
Note: If unit is built in it must be pulled out to | |||||||||
|
|
| |||||||
change the bin thermostat. | 2. | Lift spray platform up until it disconnects from its | |||||||
|
|
|
|
|
| ||||
|
|
|
|
|
| ||||
4. | Pull cap tube out from the back of the ice |
| fitting. | ||||||
|
|
| |||||||
storage bin and cap tube holder. | 3. | Pull forward and remove from the ice machine. | |||||||
|
|
|
|
|
| ||||
5. | Remove two screws and the bin thermostat | 4. | Reverse to reassemble. | ||||||
contact section from its mounting bracket. | |||||||||
|
|
| |||||||
6. | Disconnect two wires from the bin thermostat |
| Water Pump | ||||||
|
|
| |||||||
contact section and remove the thermostat from | 1. | Disconnect electrical power. | |||||||
the ice machine. | |||||||||
|
|
| |||||||
7. | Reverse to reinstall. | 2. | Remove spray platform | ||||||
|
|
| |||||||
Inlet Water Solenoid Valve | 3. | Remove back panel. | |||||||
|
|
| |||||||
|
|
|
|
|
|
|
| ||
1. | Disconnect electrical power. |
| Note: If unit is built in it must be pulled out to | ||||||
| change the water pump. | ||||||||
|
|
|
|
|
|
| |||
2. | Remove service panel. |
|
|
| |||||
|
|
| |||||||
|
|
|
|
|
| 4. | Disconnect power and ground wires from pump | ||
3. | Shut water supply OFF. |
| motor. | ||||||
4. | Disconnect inlet water supply tube from inlet | 5. | Rotate pump body CW and lift up to remove it. | ||||||
water solenoid valve. |
|
|
| ||||||
|
|
|
|
|
| 6. | Reverse to reassemble. |
5.Unplug wire harness from valve coil.
6.Remove two screws holding valve to chassis.
7.Squeeze hose clamp larger and push away from solenoid valve outlet.
8.Pull hose from outlet of valve.
September 2009
Page 25