Scotsman Ice SCCG30, SCCP30 Installation Water & Drain, Drain Pump Model drain installation

Page 10

SCCG30 & SCCP30

Service Manual

Installation: Water & Drain

The recommended water supply tubing is ¼ inch OD copper. Stainless steel flex or reinforced PVC tube may also be used. Install an easily accessible shut-off valve between the supply and the unit. This shut-off valve should not be installed behind the unit.

Note: Do not use self-piercing type valves.

1. Remove the front service panel.

Screw

Securing

Front Service

Panel

2.Route the tubing through the right hole in the back to the inlet water solenoid valve inlet.

3.Install a compression fitting on the tubing and connect to the inlet of the solenoid.

Drains

There are two types of ice machine models, one that drains by gravity and one that has an internal drain pump.

Drain Pump Model drain installation

1.Locate the coil of 3/8” ID plastic drain tubing secured to the back of the unit.

2.Route the plastic drain tube from the back of the unit to the drain connection point.

IMPORTANT NOTE: Often an air gap is required by local codes between the ice maker drain tube and the drain receptacle.

Water Inlet Tube (field supplied)

Drain Tube, Route to building drain

Back View, Drain Pump Model

September 2009

Page 10

Image 10
Contents Table of Contents IntroductionSpecifications LEG Adjustment Places Drain Flexible Tubing Cabinet LayoutAir flow Water Quality Installation OverviewFilters and Treatment Door Covering Door Panel Custom Panel Door Panel Attachment Custom Panel Installation Notes Door swing changeInstallation Water & Drain Drain Pump Model drain installationGravity Drain Electrical & Start Up Installation check listInitial Start Up Cube Size Adjustment Side Views of CubesHarvest Time Adjustment Use How to clean the condenser and winterize Condenser cleaningHow to remove scale from the ice making system Overall System InformationElectrical Components Water System Components Performance Information Refrigeration System Service Diagnosis Problem Likely Cause Probable SolutionMakes excessive noise Removal and Repair Harvest Timer Cube Size ThermostatRemoval and Repair Cabinet Removal SCCG30 & SCCP30 Refrigeration Service