VHX SERIES STEAMER - TROUBLESHOOTING
TROUBLESHOOTING
BOILER BASE CONTROLS
WARNING: CERTAIN PROCEDURES IN THIS SECTION REQUIRE ELECTRICAL TESTS OR MEASUREMENTS WHILE POWER IS APPLIED TO THE MACHINE. EXERCISE EXTREME CAUTION AT ALL TIMES. IF TEST POINTS ARE NOT EASILY ACCESSIBLE, DISCONNECT POWER, ATTACH TEST EQUIPMENT AND REAPPLY POWER TO TEST.
Models with new style controls: Before performing any of the troubleshooting checks listed below, remove the cover from the main control box and check the condition of the LED’S on the relay board for the status of the condition or component in the operating sequence. By utilizing the troubleshooting LED’S, the Service Technician can quickly and easily determine if a component is functioning properly or in need of repair. Refer to "RELAY BOARD" under "ELECTRICAL OPERATION".
SYMPTOM |
| POSSIBLE CAUSES | |
|
|
| |
Steamer does not operate. | 1. | No power to steamer. | |
| 2. | F1 Fuse open. | |
| 3. | Malfunctioning power switch. | |
| 4. | Malfunctioning power switch latching relay (old style controls | |
|
| only). | |
|
|
| |
Steamer ON, cannot reset low water | 1. | Low water level in boiler. | |
condition. |
| A. Water inlet valve(s) OFF. | |
|
| B. Fill solenoid not receiving power, clogged or | |
|
| malfunctioning. | |
| 2. | Manual blowdown valve on water level probe housing open. | |
| 3. | Improper ground. | |
| 4. | Lime scale | |
| 5. | Malfunctioning reset switch. | |
| 6. | Malfunctioning auxiliary water level control board. | |
|
|
| |
Steamer ON, cannot reset high pressure | 1. | Excessive pressure in boiler. | |
condition. | 2. | Malfunctioning reset switch. | |
| 3. | Malfunctioning high pressure limit switch. | |
| 4. | Malfunctioning pressure switch latching relay (old style controls | |
|
| only). | |
|
|
| |
Steamer ON, reset switch pressed but | 1. | Blower malfunctioning or loose connection on blower cord. | |
blower does not operate when calling for | 2. | 24 VAC transformer malfunctioning. | |
heat. | 3. | Malfunction in cycling pressure switch. | |
(boiler pressure within operating limits) | |||
4. | Malfunctioning "Low Water" or "Hi Pressure" light not indicating | ||
| |||
|
| true condition. | |
| 5. | Blower relay malfunctioning (old style controls only). | |
|
|
|