Conair
MPW, MPA
manual
Troubleshooting
Specs
Install
Parts/Diagrams
Shut Down Alarms
Connecting Main Power Supply
Maintenance
Dip switch Configuration
Cause of a Problem
Resetting Overloads
Page 1
Page 1
Page 2
Image 1
Page 1
Page 2
Contents
Page
Date Manual Number UGH004/0999 Serial numbers Model numbers
Introduction
Table of Contents
Troubleshooting
Introduction
HOW Guide is Organized
Purpose User Guide
Your Responsibility AS a User
Read this SO no ONE Gets Hurt
Page
Description
CHILLER?
What is the Microkool
Typical Applications
HOW IT Works Water Cooled
HOW IT Works AIR Cooled
High Efficiency Compressors
Features
Psi Pressure
Specifications MPW Water Cooled
MPA-5
Specifications MPA AIR Cooled
Freeze Protection Requirements
Freezing Points of Aqueous Ethylene Glycol Solutions
Installation
Boxes
Unpacking
MicroKool Portable Chillers come fully assembled
Make sure the installation area provides
Preparing for Installation
Install plumbing for process and cooling lines
Install pipe to the rear of the chiller
Connecting Process Water Supply Lines
Remove the shipping pipe plug from the female
Coat the pipe threads with thread sealant
Open the unit’s electrical enclosure
Connecting Main Power Supply
Apply power to the unit
Testing the Installation
Turn on the condenser water supply MPW
Units and check for leaks. If any leaks appear, stop
Entering Setpoint Deviation Parameters
Dip switch Configuration
Initial Setup
Open the electrical enclosure Change Dip Switch 1 to
Changing Temperature Units
Open the electrical enclosure Set dip switch 3 to on
Disconnect and lock out main power to the unit
Select a new passcode using
Setpoint adjustment buttons
Open the electrical
Press the RUN button to save the passcode
Follow Steps 1 through 5
Select a new control point using the Display button
Selecting Temperature Control Point
Press the RUN button to save the control point
Set dip switch 5 to
Insert the two power leads from the device
Installing Auto Start Feature
When Auto Start is enabled
Set dip switch 4 to the on position
To disable Auto Start
Activating SPI Communication
Apply power to the chiller Enter the passcode, if necessary
Connect the host machine to the chiller
Enter the node address
Operation
Setpoint display
PC-1 Control Features
Pumpdown On/Off
PC-2 Control Features
To raise and swivel the control panel
Positioning Control Panel
To lower the control panel
To detach the PC-2 control panel
Press Setpoint to select the parameter you want to change
Entering a Passcode
Enter the passcode
Starting the Chiller
Stopping the Chiller
Using Pumpdown Feature
To shut down the unit Press Stop
Press Button to turn on Pumpdown
Performing AN Auto Tune
Insufficient setpoint/process deviation
Page
Maintenance
Preventative Maintenance Schedule
Quarterly every 3 months
Inspect power cords, wires and electrical connections
Cleaning Condensers
Cleaning Evaporators
Locate the fill port at Back of the chiller
Refilling the Tank
To fill the reservoir
If the charge is low, recharge the system
Checking Refrigerant Charge
Performing System Tests
Set dip switches 3
Press To shut down the chiller
Then open the electrical enclosure
KEY/DISPLAY Test
Connect all inputs to the system
Input Test
Press any key to display the first test menus
Select the Input Test menu
Connect all outputs to the system
Output Test
Select the Output Test menu
Disabling or Enabling Output Monitors
Select the OM Enable/Disable menu
Save changes and exit the output menu
Release the Setpoint key
Calibrating Temperature Sensors
Press the up key to begin calibrating
Exit Calibration Mode
Wait until the control displays don or bad
Press Select
Index through test menus to the operating log
Logging Operating Hours
Exit the Operating Hours Log
Troubleshooting
FEW Words
Before Beginning
Verify that you have manuals for other equip
Messages shown on the control panel. These
Cause of a Problem
HOW to Identify
Motor?
Supplied to the pump
Is the required water flow
Greater than the pump’s
Loose?
Is the thermocouple
Level Switch fuse Has the indicated device
Ply wire leads become
Has one of the main sup
Disconnected?
Compressor
Refrigerant pressure is either too low or too high
Shut Down Alarms
All models
Air-cooled units
Installed correctly?
Is the freezestat setting
Freeze Stat Input is open Is there sufficient fluid
Flow through he evapora
Cable?
Is something wrong with
System Alarms
Chiller Will not Power UP
If fuses continue to fail
Checking Replacing Fuses
On the front panel counterclockwise to open
Replace the fuse. The fuses are located on the mother
Check the overload
Resetting Overloads
Locate the pump overload module attached
Replacing the Motherboard
Replacing Compressor Contactor
Reverse this procedure to install the new con
Remove and discard the old contactor
Checking Unloader Valve
Replacing the Freezestat
From outside the United States, call
WE’RE Here to Help
Appendix A-2
SPI Command Pairs
SPI Commands Supported by Conair Microkool
Status, Process
SPI Status Words
Status, Machine
Appendix B-4
PARTS/DIAGRAMS
PD-2
PD-3
PD-4
PD-5
Related pages
PRODUCT SPECIFICATIONS for Husqvarna 7021CH1
Top
Page
Image
Contents