Maytag DN5000, DN3000 manual Testmode Test Routine, Relays Relay Test, Password Password Routine

Page 11

PROGRAMMING

“TESTMODE” - TEST ROUTINE

This function allows you to diagnose different functions of the vender.

Press key number 4 and the display will show “TESTVEND”.

Press key number 2 or 3 to scroll through the test routines available.

Press key number 1 to return to “TESTMODE”.

“TESTVEND” - Vend Testing

This function allows you to test vend each column. Press key number 4 and the display will show “COL A1”.

Press key numbers 2 or 3 to scroll through the columns available to run in motor test. Press key number 4 to run the motor of the column displayed.

Press key number 1 will return to “TESTVEND”. Press key number 2 to scroll to next test mode.

“TEST SEL” - Select Switch Test

This function allows you to test each selection.

Press key number 4 and the display will show “SEL 4”. Then press any key and the display will show the last key number pressed.

Press and hold key number 1 for approximately 5 seconds will return to “TEST SEL”. Press key number 2 to scroll to the next test mode.

“DISPLAY” - Display Test

This function allows you to test all segments in the display.

Press key number 4 and the display segments will illuminate in the following manner; “*0.” will scroll continuously.

Press key number 1 to return to “DISPLAY”. Press key number 2 to scroll to next test mode.

“RELAYS” - RELAY TEST

This function allows you to test the relay electronic control of the compressor (“COMPR #”), the evaporator fan(s) (“FAN #”), and the sign front light (“LIGHT#”).

CAUTION: Disconnect power to the compressor before testing the compressor relay. Failure to disconnect power to the compressor before testing the relay could result in damaging the compressor.

Press key number 4 and the display will show “COMPR#”, where # is the state of the relay -

0 = not activated or off; 1 = activated or on . Press key number 4 to toggle the relay on and off. Press key number 2 to scroll to “FAN#”, where # is the state of the relay - 0 = not activated or off, 1 = activated or on. Press key number 4 to toggle the fan(s) on and off.

Press key number 2 to scroll to “LIGHT#”, where # is the state of the relay - 0 = not activated or off; 1 = activated or on. Press key number 4 to toggle the lights on and off.

Press key number 1 to return to “TESTMODE”. Press key number 2 to scroll to “PASSWORD”.

* “PASSWORD” - PASSWORD ROUTINE

This function allows you to enter the following routines which are not accessible until the operator enters a password, which is set as 4-2-3-1. To enter the password, press key number 4 until the display goes blank. Then press key number 2, then 3, then 1, and then 4, and “CASH” should appear on the display. If not entered properly, the display will return to “PASSWORD” after approximately 16 seconds. If entered correctly, the display will go to the next function “CASH”.

11 of 90

Image 11
Contents Glass Front Vender by Maytag DN5000 Table of Contents Product Identification Vender Safety PrecautionsPhysical Characteristics Unpacking the Venders Electric Power NeededCoin Changers & Other Accessories Receiving InspectionLoading the Vender Placing the Vender on LocationLevel the Vender Space the VenderMDB Units Installation and Setup InstructionsProgramming Menu Error Error Routine Normal ModeService Mode External Menu ModeChanger Changer Summary Errors Control Control System Summary ErrorsSelectsw Select Switch Summary Errors Rvend Remote Vend Mechanism USD Error Bill VAL Bill Validator Summary ErrorsCard RDR Card Reader Summary Errors Online Online Module ErrorTubefill Tube Fill Routine Refrig Refrigeration Summary ErrorsDNC ERR Dixie-Narco Corporation Summary Errors Coinpayo Coin Payout RoutineRelays Relay Test Password Password RoutineTestmode Test Routine Sales Sales Counter Routine Price Price Setting RoutineCash Cash Counter Routine OPTION2 STS Prog Space to Sales RoutineCON 3 Configuration Switch 3 POS Message Config Machine ConfigurationCON 1 Configuration Switch 1 Multi-Price Setting Mode CON 2 Configuration Switch 2 Optional Features EnableCON 9 Configuration Switch 9 Multi Vend CON 6 Configuration Switch 6 ReservedCON 7 Configuration Switch 7 Save Credit CON 8 Configuration Switch 8 Force VendCorr CHG Correct Change Value Preview Preview Data Password RoutineChange Correct Change only Control Routine Conoverx Allow Consumer OverpayLanguage Language Routine Time Time and Date Setting RoutineStrt DAY Day to Start Setting DST Daylight Saving Time SettingEnablex Lighting Conservation Control Enable Routine Strt TIM Start Lighting Conservation Setting lights offRefrig Refrigeration Routine Strt TIM Start Selection Blocking Routine Degrees Degree Fahrenheit / Celsius Setting RoutineDisplyx POS Temperature Display Enable Routine Select Selection To Be Affected By Blocking Strt DAY Day of Week Start SettingStop DAY Day of Week Stop Setting Stop TIM Stop Selection Blocking RoutineSELBLCK2 Block Selection Bank 2 Routine Lightx Lighting / P.O.S. Display ControlDiscount Discount Setting Routine Override Manual Switch Override Routine Rvndmech Remote Vend Mechanism Routine Health Health Setting Routine Grabmode Grabmode Setting RoutineSelect Selections To Be Affected By Health Protection Enable X Health Enable RoutineRecheckx Recheck Feature Return Return to Sales ModeCOCA-COLA Programming Method Quick Reference Menu Prompts Eprom Replacement PowerCleaning Refrigeration Unit Major Component DescriptionUniversal KO Board 0077-8272CB & Higher Universal KO Board prior to 0077-8272CB Programming Machine Board prior to 0077-8272CB Wiring Diagram 9 Column Wiring Diagram 6 Column Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Conveyor Issues Elevator Issues Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting ICE / Frost on Evaporator Parts Index Machine Front View Part Description DN5000 DN3000Cabinet Detail Cabinet Assembly Export Service Door Front Part Number Part Description DN5000 & DN3000 Service Door FrontCGF Coke DGF Dasani Glass Glass Front Service Door Inside DN5000 & DN3000 Service Door Inside Tray Assembly Gate Assembly with Kicker AC Distribution BOX Domestic Shown DN5000 & DN3000 AC Distribution BOX Elevator DN5000 & DN3000 Elevator Conveyor Conveyor Assembly Wiring not shown Lighting A1A Refrigeration DN5000 & DN3000 Refrigeration Electronics Part Number Part Description NEW Remanufactured DN5000 & DN3000 ElectronicsPart Part Description From / to Number HarnessesCGF Coke DGF Dasani Glass Front Labels / Decals / MiscScrews and Nuts Screws & Nuts Screws & Nuts Washers / Bolts / Misc Hardware Washers , BOLTS, and MISC. Hardware Washers , BOLTS, and MISC. Hardware

DN5000, DN3000 specifications

The Maytag DN3000 and DN5000 are two robust commercial dishwashers designed to handle the rigorous demands of busy kitchens, making them ideal for restaurants, hotels, and catering operations. What sets these models apart is their combination of efficiency, performance, and durability, which are essential for maintaining high standards of cleanliness and sanitation.

Both the DN3000 and DN5000 feature an advanced wash system that ensures thorough cleaning of dishes, pots, pans, and utensils. The powerful wash pumps are designed to deliver optimal spray coverage, while the stainless steel construction enhances durability and corrosion resistance. This translates into longer-lasting equipment that can withstand the wear and tear of a high-volume environment.

In terms of capacity, the DN3000 can handle up to 300 racks per hour, while the DN5000 steps up the game with a capacity of 500 racks per hour. This makes the DN5000 particularly suited for establishments with heavy dishwashing loads, where speed and efficiency are paramount. Both models are equipped with a built-in booster heater that ensures optimal water temperatures for effective sanitization, which is critical for health and safety compliance.

User-friendly controls are another highlight of these dishwashers. The intuitive digital display allows operators to easily select wash cycles, monitor cycle progress, and troubleshoot issues. Additionally, both models feature automatic drain systems that help prevent clogs and reduce maintenance interruptions.

Energy and water efficiency are also key characteristics of the Maytag DN3000 and DN5000. These dishwashers are designed to minimize water consumption, making them environmentally friendly options that can help lower operational costs. With their ENERGY STAR certification, they meet energy-efficiency guidelines set by the U.S. Environmental Protection Agency.

Both models also come with customizable rack options to maximize washing effectiveness for various types of dishware, from flat dishes to larger pots and pans. Safety features like lockable controls and built-in safety interlocks further enhance operability, providing peace of mind for kitchen staff.

In summary, the Maytag DN3000 and DN5000 dishwashers are engineered for optimal performance in the fast-paced commercial kitchen setting. With their impressive capacity, advanced wash technology, user-friendly controls, and energy efficiency, these models are reliable choices for any food service operation looking to maintain high standards of cleanliness and efficiency.