Maytag manual DN5000 & DN3000 Refrigeration, Part Number Part Description

Page 80

PARTS

 

 

DN5000 & DN3000 REFRIGERATION

 

 

 

ITEM

PART NUMBER

PART DESCRIPTION

1

626,041,60x.x4

Domestic Kit – Refrigeration System 2000C-A 115/60

1A

626,040,00x.x3

Refrigeration System 2000C-A 115/60, Domestic/Japan

1B

626,041,00x.x3

Refrigeration System 2020C-A, Export

1C

626,041,90x.x3

Refrigeration System 2030C-A, Export Korea

2A

626,040,60x.x3

Compressor Assembly 115 / 60, Domestic/Japan

2B

626,041,30x.x3

Compressor Assembly 220-240/50, Export

2C

626,042,30x.x3

Compresso Assembly 208-230/60, Export Korea

3A

802,502,22x.x1

Compressor AT6213Z 115 / 60, Domestic/Japan

3B

802,502,25x.x1

Compressor A220-240 / 50 T6213Z, Export

3C

802,502,30x.x1

Compressor “A” T6213Z 208-230/60, Export Korea

4A

802,502,23x.x1

Overload, T1 MST16AFN-3001, Domestic/Japan

4B

802,502,26x.x1

Overload, T1 MRP20APK-34, Export

4C

802,502,31x.x1

Overload, T1 MRT18GL 3001, Korea

5A

802,500,94x.x1

Relay, T1 9660-041-180, Domestic/Japan

5B

802,502,27x.x1

Relay, T1 9660-041-158, Export

5C

802,502,32x.x1

Relay, T1 9660-041-179 EM, Korea

6

802,502,01x.x1

Cover, Overload / Relay Tecumseh

7A

802,502,24x.x1

Capacitor Start 189227, Domestic/Japan

7B

802,502,28x.x1

Capacitor Start 88-108MFD / 250 V 50 Hz., Export

7C

802,502,33x.x1

Capacitor Start 66-77 MFD/330V50/60HZ, Korea

8

802,501,18x.x1

Capacitor End Cap Bottom Hole

9

802,501,87x.x1

Bracket Capacitor Assembly

10A

801,812,61x.x1

Drain Pan, Condensate Domestic

10B

801,813,55x.x1

Drain Pan, Condensate Export

11A

626,040,70x.x3

Assembly, Condenser Fan 16 W, 10 Inch Domestic/Japan

11B

626,041,40x.x3

Assembly, Condenser 16W 220V Export/Korea

12A

804,501,14x.x1

Condenser Fan Motor, 16W

12B

804,501,18x.x1

Condenser Fan Motor, 16W 220V

13

902,100,29x.x1

Silencer

14

801,305,67x.x1

Fan Blade, Condenser FV100CW25S

15

900,800,85x.x1

Speed Nut

16

802,600,64x.x1

Condenser

17

802,401,30x.x1

Dryer

18

902,000,57x.x1

Grommet Compressor

19

802,600,63x.x1

Evaporator

20

802,401,35x.x1

Accumulator

21A

802,800,60x.x1

Defrost Control

21B

801,902,75x.x1

Defrost Control Vinyl Tube

21C

626,020,34x.x3

Defrost Thermostat Guard

22A

626,040,80x.x3

Assembly Drain Pan, Evaporator

22B

801,814,62x.x1

Drain Pan

22C

801,806,05x.x1

Drain Tube

22D

900,301,79x.x1

Drain Tube Nut

22E

901,900,50x.x1

Drain Hose

22F

900,901,03x.x1

Drain Hose Clamp

23

626,040,04x.x3

Evaporator Fan Shroud

24A

804,501,09x.x1

Evaporator Fan Motor Assembly, Domestic/Japan

24B

804,501,11x.x1

Evaporator Fan 8” 9W, 220-230 / 50, Export

25A

801,812,63x.x1

Side Gasket, Drain Pan

25B

801,812,64x.x1

Front Gasket, Drain Pan

26

626,040,09x.x3

Refrigeration Side Brace

27

804,919,66x.x1

Encapsulated Temperature Sensor

Part numbers subject to change with out notice.

80 of 90

Image 80
Contents Glass Front Vender by Maytag DN5000 Table of Contents Product Identification Vender Safety PrecautionsPhysical Characteristics Electric Power Needed Coin Changers & Other AccessoriesReceiving Inspection Unpacking the VendersPlacing the Vender on Location Level the VenderSpace the Vender Loading the VenderInstallation and Setup Instructions MDB UnitsNormal Mode Service ModeExternal Menu Mode Programming Menu Error Error RoutineChanger Changer Summary Errors Control Control System Summary ErrorsSelectsw Select Switch Summary Errors Bill VAL Bill Validator Summary Errors Card RDR Card Reader Summary ErrorsOnline Online Module Error Rvend Remote Vend Mechanism USD ErrorRefrig Refrigeration Summary Errors DNC ERR Dixie-Narco Corporation Summary ErrorsCoinpayo Coin Payout Routine Tubefill Tube Fill RoutineRelays Relay Test Password Password RoutineTestmode Test Routine Sales Sales Counter Routine Price Price Setting RoutineCash Cash Counter Routine STS Prog Space to Sales Routine OPTION2Config Machine Configuration CON 1 Configuration Switch 1 Multi-Price Setting ModeCON 2 Configuration Switch 2 Optional Features Enable CON 3 Configuration Switch 3 POS MessageCON 6 Configuration Switch 6 Reserved CON 7 Configuration Switch 7 Save CreditCON 8 Configuration Switch 8 Force Vend CON 9 Configuration Switch 9 Multi VendPreview Preview Data Password Routine Change Correct Change only Control RoutineConoverx Allow Consumer Overpay Corr CHG Correct Change ValueTime Time and Date Setting Routine Language Language RoutineDST Daylight Saving Time Setting Enablex Lighting Conservation Control Enable RoutineStrt TIM Start Lighting Conservation Setting lights off Strt DAY Day to Start SettingRefrig Refrigeration Routine Strt TIM Start Selection Blocking Routine Degrees Degree Fahrenheit / Celsius Setting RoutineDisplyx POS Temperature Display Enable Routine Strt DAY Day of Week Start Setting Stop DAY Day of Week Stop SettingStop TIM Stop Selection Blocking Routine Select Selection To Be Affected By BlockingLightx Lighting / P.O.S. Display Control SELBLCK2 Block Selection Bank 2 RoutineDiscount Discount Setting Routine Override Manual Switch Override Routine Rvndmech Remote Vend Mechanism Routine Grabmode Grabmode Setting Routine Health Health Setting RoutineEnable X Health Enable Routine Recheckx Recheck FeatureReturn Return to Sales Mode Select Selections To Be Affected By Health ProtectionCOCA-COLA Programming Method Quick Reference Menu Prompts Eprom Replacement PowerCleaning Major Component Description Refrigeration UnitUniversal KO Board 0077-8272CB & Higher Universal KO Board prior to 0077-8272CB Programming Machine Board prior to 0077-8272CB Wiring Diagram 9 Column Wiring Diagram 6 Column Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Conveyor Issues Elevator Issues Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting ICE / Frost on Evaporator Parts Index Machine Front View DN5000 DN3000 Part DescriptionCabinet Detail Cabinet Assembly Export Service Door Front Part Number Part Description DN5000 & DN3000 Service Door FrontCGF Coke DGF Dasani Glass Glass Front Service Door Inside DN5000 & DN3000 Service Door Inside Tray Assembly Gate Assembly with Kicker AC Distribution BOX Domestic Shown DN5000 & DN3000 AC Distribution BOX Elevator DN5000 & DN3000 Elevator Conveyor Conveyor Assembly Wiring not shown Lighting A1A Refrigeration DN5000 & DN3000 Refrigeration Electronics DN5000 & DN3000 Electronics Part Number Part Description NEW RemanufacturedHarnesses Part Part Description From / to NumberLabels / Decals / Misc CGF Coke DGF Dasani Glass FrontScrews and Nuts Screws & Nuts Screws & Nuts Washers / Bolts / Misc Hardware Washers , BOLTS, and MISC. Hardware Washers , BOLTS, and MISC. Hardware

DN5000, DN3000 specifications

The Maytag DN3000 and DN5000 are two robust commercial dishwashers designed to handle the rigorous demands of busy kitchens, making them ideal for restaurants, hotels, and catering operations. What sets these models apart is their combination of efficiency, performance, and durability, which are essential for maintaining high standards of cleanliness and sanitation.

Both the DN3000 and DN5000 feature an advanced wash system that ensures thorough cleaning of dishes, pots, pans, and utensils. The powerful wash pumps are designed to deliver optimal spray coverage, while the stainless steel construction enhances durability and corrosion resistance. This translates into longer-lasting equipment that can withstand the wear and tear of a high-volume environment.

In terms of capacity, the DN3000 can handle up to 300 racks per hour, while the DN5000 steps up the game with a capacity of 500 racks per hour. This makes the DN5000 particularly suited for establishments with heavy dishwashing loads, where speed and efficiency are paramount. Both models are equipped with a built-in booster heater that ensures optimal water temperatures for effective sanitization, which is critical for health and safety compliance.

User-friendly controls are another highlight of these dishwashers. The intuitive digital display allows operators to easily select wash cycles, monitor cycle progress, and troubleshoot issues. Additionally, both models feature automatic drain systems that help prevent clogs and reduce maintenance interruptions.

Energy and water efficiency are also key characteristics of the Maytag DN3000 and DN5000. These dishwashers are designed to minimize water consumption, making them environmentally friendly options that can help lower operational costs. With their ENERGY STAR certification, they meet energy-efficiency guidelines set by the U.S. Environmental Protection Agency.

Both models also come with customizable rack options to maximize washing effectiveness for various types of dishware, from flat dishes to larger pots and pans. Safety features like lockable controls and built-in safety interlocks further enhance operability, providing peace of mind for kitchen staff.

In summary, the Maytag DN3000 and DN5000 dishwashers are engineered for optimal performance in the fast-paced commercial kitchen setting. With their impressive capacity, advanced wash technology, user-friendly controls, and energy efficiency, these models are reliable choices for any food service operation looking to maintain high standards of cleanliness and efficiency.