Maytag DN5000, DN3000 manual Language Language Routine, Time Time and Date Setting Routine

Page 17

PROGRAMMING

*”LANGUAGE” - LANGUAGE ROUTINE

This function is used to set the language that will be used for display messages. Note: This does not change the menu prompts.

Press key number 4 and the display will show the language currently set in the controller. Press key number 2 or 3 to scroll through the languages available.

ENGLISH

-

English

ITALIAN

-

Italian

SLOVENE

-

Slovene

FRENCH

-

French

PORTUGES

-

Portuguese

FINNISH

-

Finnish

GERMAN

-

German

SPANISH

-

Spanish

NORWEG

-

Norwegian

With the language you wish to enter showing on the display, press key number 4.

The display will return to “LANGUAGE”.

Press key number 2 to scroll to next routine.

*”TIME” - TIME AND DATE SETTING ROUTINE

This function is used to set the year, month, date, and hour (military 24 hour clock).

Press key number 4 and “ENABLE X” will show on display.

“ENABLEX” - Time and Date Enable Routine

Press key number 4 and ENABLE0 = disabled or ENABLE1 = enabled will show on display. Press key number 2 to scroll between ENABLE0 and ENABLE1.

Press key number 4 with the display showing the setting you wish to use and display will return to “ENABLEX”.

Press key number 2 to scroll to “YEAR”.

“YEAR” - Year Setting (00 to 99)

Press key number 4 and the current year setting will show on display. Press key number 2 or 3 to change the last 2 digits of the year (00 to 99).

Press key number 4 with the display showing the year you wish to use and display will return to “YEAR”. Press key number 2 to scroll to “MONTH”.

“MONTH” - Month Setting (01 to 12)

Press key number 4 and the current 2 digit month setting will show on display. Press key number 2 or 3 to change the month (01 to 12).

Press key number 4 with the display showing the month you wish to use and display will return to “MONTH”.

Press key number 2 to scroll to “DATE”.

“DAY” - Day of Month Setting (1 to 31)

Press key number 4 and the current 2 digit day of month setting will show on display. Press key number 2 or 3 to change the day of month (1 to 31).

Press key number 4 with the display showing the day you wish to use and display will return to “DAY”. Press key number 2 to scroll to “HOUR”.

“HOUR” - Hour and Minute Setting (0000 to 2359)

Press key number 4 and the current 4 digit hour and minute setting will be displayed (24 hour).

The hour setting will be blinking to indicate it can be changed. Press key number 2 or 3 to change the hour setting. Press key number 4 to save and the minute setting will start blinking to indicate it can be changed. Press key number 2 or 3 to change the minute setting. Press key number 4 will save and return display to “HOUR”.

Press key number 2 to scroll to “DST”.

17 of 90

Image 17
Contents Glass Front Vender by Maytag DN5000 Table of Contents Product Identification Vender Safety PrecautionsPhysical Characteristics Coin Changers & Other Accessories Electric Power NeededReceiving Inspection Unpacking the VendersLevel the Vender Placing the Vender on LocationSpace the Vender Loading the VenderMDB Units Installation and Setup InstructionsService Mode Normal ModeExternal Menu Mode Programming Menu Error Error RoutineChanger Changer Summary Errors Control Control System Summary ErrorsSelectsw Select Switch Summary Errors Card RDR Card Reader Summary Errors Bill VAL Bill Validator Summary ErrorsOnline Online Module Error Rvend Remote Vend Mechanism USD ErrorDNC ERR Dixie-Narco Corporation Summary Errors Refrig Refrigeration Summary ErrorsCoinpayo Coin Payout Routine Tubefill Tube Fill RoutineRelays Relay Test Password Password RoutineTestmode Test Routine Sales Sales Counter Routine Price Price Setting RoutineCash Cash Counter Routine OPTION2 STS Prog Space to Sales RoutineCON 1 Configuration Switch 1 Multi-Price Setting Mode Config Machine ConfigurationCON 2 Configuration Switch 2 Optional Features Enable CON 3 Configuration Switch 3 POS MessageCON 7 Configuration Switch 7 Save Credit CON 6 Configuration Switch 6 ReservedCON 8 Configuration Switch 8 Force Vend CON 9 Configuration Switch 9 Multi VendChange Correct Change only Control Routine Preview Preview Data Password RoutineConoverx Allow Consumer Overpay Corr CHG Correct Change ValueLanguage Language Routine Time Time and Date Setting RoutineEnablex Lighting Conservation Control Enable Routine DST Daylight Saving Time SettingStrt TIM Start Lighting Conservation Setting lights off Strt DAY Day to Start SettingRefrig Refrigeration Routine Strt TIM Start Selection Blocking Routine Degrees Degree Fahrenheit / Celsius Setting RoutineDisplyx POS Temperature Display Enable Routine Stop DAY Day of Week Stop Setting Strt DAY Day of Week Start SettingStop TIM Stop Selection Blocking Routine Select Selection To Be Affected By BlockingSELBLCK2 Block Selection Bank 2 Routine Lightx Lighting / P.O.S. Display ControlDiscount Discount Setting Routine Override Manual Switch Override Routine Rvndmech Remote Vend Mechanism Routine Health Health Setting Routine Grabmode Grabmode Setting RoutineRecheckx Recheck Feature Enable X Health Enable RoutineReturn Return to Sales Mode Select Selections To Be Affected By Health ProtectionCOCA-COLA Programming Method Quick Reference Menu Prompts Eprom Replacement PowerCleaning Refrigeration Unit Major Component DescriptionUniversal KO Board 0077-8272CB & Higher Universal KO Board prior to 0077-8272CB Programming Machine Board prior to 0077-8272CB Wiring Diagram 9 Column Wiring Diagram 6 Column Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Conveyor Issues Elevator Issues Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting ICE / Frost on Evaporator Parts Index Machine Front View Part Description DN5000 DN3000Cabinet Detail Cabinet Assembly Export Service Door Front Part Number Part Description DN5000 & DN3000 Service Door FrontCGF Coke DGF Dasani Glass Glass Front Service Door Inside DN5000 & DN3000 Service Door Inside Tray Assembly Gate Assembly with Kicker AC Distribution BOX Domestic Shown DN5000 & DN3000 AC Distribution BOX Elevator DN5000 & DN3000 Elevator Conveyor Conveyor Assembly Wiring not shown Lighting A1A Refrigeration DN5000 & DN3000 Refrigeration Electronics Part Number Part Description NEW Remanufactured DN5000 & DN3000 ElectronicsPart Part Description From / to Number HarnessesCGF Coke DGF Dasani Glass Front Labels / Decals / MiscScrews and Nuts Screws & Nuts Screws & Nuts Washers / Bolts / Misc Hardware Washers , BOLTS, and MISC. Hardware Washers , BOLTS, and MISC. Hardware

DN5000, DN3000 specifications

The Maytag DN3000 and DN5000 are two robust commercial dishwashers designed to handle the rigorous demands of busy kitchens, making them ideal for restaurants, hotels, and catering operations. What sets these models apart is their combination of efficiency, performance, and durability, which are essential for maintaining high standards of cleanliness and sanitation.

Both the DN3000 and DN5000 feature an advanced wash system that ensures thorough cleaning of dishes, pots, pans, and utensils. The powerful wash pumps are designed to deliver optimal spray coverage, while the stainless steel construction enhances durability and corrosion resistance. This translates into longer-lasting equipment that can withstand the wear and tear of a high-volume environment.

In terms of capacity, the DN3000 can handle up to 300 racks per hour, while the DN5000 steps up the game with a capacity of 500 racks per hour. This makes the DN5000 particularly suited for establishments with heavy dishwashing loads, where speed and efficiency are paramount. Both models are equipped with a built-in booster heater that ensures optimal water temperatures for effective sanitization, which is critical for health and safety compliance.

User-friendly controls are another highlight of these dishwashers. The intuitive digital display allows operators to easily select wash cycles, monitor cycle progress, and troubleshoot issues. Additionally, both models feature automatic drain systems that help prevent clogs and reduce maintenance interruptions.

Energy and water efficiency are also key characteristics of the Maytag DN3000 and DN5000. These dishwashers are designed to minimize water consumption, making them environmentally friendly options that can help lower operational costs. With their ENERGY STAR certification, they meet energy-efficiency guidelines set by the U.S. Environmental Protection Agency.

Both models also come with customizable rack options to maximize washing effectiveness for various types of dishware, from flat dishes to larger pots and pans. Safety features like lockable controls and built-in safety interlocks further enhance operability, providing peace of mind for kitchen staff.

In summary, the Maytag DN3000 and DN5000 dishwashers are engineered for optimal performance in the fast-paced commercial kitchen setting. With their impressive capacity, advanced wash technology, user-friendly controls, and energy efficiency, these models are reliable choices for any food service operation looking to maintain high standards of cleanliness and efficiency.