Maytag DN3000 Lightx Lighting / P.O.S. Display Control, SELBLCK2 Block Selection Bank 2 Routine

Page 22

PROGRAMMING

“LIGHTX” - Lighting / P.O.S. Display Control

This function is used to turn the lights (if supported) and P.O.S. Display Message off during selection blocking period 1. 0 = disable or on; 1 = enable or off.

Press key number 4 and the “#” will start flashing.

Press key number 2 or 3 to scroll between “LIGHT0” and “LIGHT1”. Press key number 4 with the display showing the setting you wish to use. Display will return to “LIGHTX”.

Press key number 1 to return to “SELBLCK1”. Press key number 2 to scroll to “SELBLCK2”.

*”SELBLCK2" - BLOCK SELECTION BANK 2 ROUTINE

This function is a second set used to set selection(s) which will be blocked during certain periods of the day. Press key number 4 will enter “ENABLEX”.

“ENABLEX” - Blocking Enable Routine.

Set this function using instruction for “ENABLEX” in “SELBLCK1”.

“STRT TIM” - Start Selection Blocking Routine

This function is used to set the day(s) and times to start selection blocking.

Press selection button 4 and “STRT DAY” will show on the display.

“STRT DAY” - Day of Week Start Setting

Set this feature using instructions for “SELBLCK1”, “STRT TIM”, “STRT DAY”.

“STRT HR” - Start Hour and Minute Setting

Set this function using instructions for “SELBLCK1”, “STRT TIM”, “STRT HR”.

“STOP TIM” - Stop Selection Blocking Routine.

This function is used to set the day(s) and times to stop selection blocking.

Press key number 4 and “STOP DAY” will show on the display.

“STOP DAY” - Day of Week Stop Setting

Set this function using instructions for “SELBLCK1”, “STOP TIM”, “STOP DAY”.

“STOP HR” - Stop Hour and Minute Setting

Set this function using instructions for “SELBLCK1”, “STOP TIM”, “STOP HR”.

Press key number 1 to return to “STOP TIM”.

Press key number 2 to scroll to “SELECT”.

“SELECT” - Selection To Be Affected By Blocking

This function is used to set selection(s) which will be blocked during certain periods of the day. Set this function using instructions for “SELBLCK1”, “SELECT”.

Press key number 1 to return to “SELECT”. Press key number 2 to scroll to “LIGHTX”.

“LIGHTX” - Lighting / P.O.S. Display Control

This function is used to turn the lights (if supported) and P.O.S. Display Message off during selection blocking period 2.

Set this function using instructions for “SELBLCK1”, “LIGHT”. Press key number 1 to return to “SELBLCK2”.

Press key number 2 to scroll to “DISCOUNT”.

22 of 90

Image 22
Contents Glass Front Vender by Maytag DN5000 Table of Contents Physical Characteristics Vender Safety PrecautionsProduct Identification Receiving Inspection Electric Power NeededCoin Changers & Other Accessories Unpacking the VendersSpace the Vender Placing the Vender on LocationLevel the Vender Loading the VenderInstallation and Setup Instructions MDB UnitsExternal Menu Mode Normal ModeService Mode Programming Menu Error Error RoutineSelectsw Select Switch Summary Errors Control Control System Summary ErrorsChanger Changer Summary Errors Online Online Module Error Bill VAL Bill Validator Summary ErrorsCard RDR Card Reader Summary Errors Rvend Remote Vend Mechanism USD ErrorCoinpayo Coin Payout Routine Refrig Refrigeration Summary ErrorsDNC ERR Dixie-Narco Corporation Summary Errors Tubefill Tube Fill RoutineTestmode Test Routine Password Password RoutineRelays Relay Test Cash Cash Counter Routine Price Price Setting RoutineSales Sales Counter Routine STS Prog Space to Sales Routine OPTION2CON 2 Configuration Switch 2 Optional Features Enable Config Machine ConfigurationCON 1 Configuration Switch 1 Multi-Price Setting Mode CON 3 Configuration Switch 3 POS MessageCON 8 Configuration Switch 8 Force Vend CON 6 Configuration Switch 6 ReservedCON 7 Configuration Switch 7 Save Credit CON 9 Configuration Switch 9 Multi VendConoverx Allow Consumer Overpay Preview Preview Data Password RoutineChange Correct Change only Control Routine Corr CHG Correct Change ValueTime Time and Date Setting Routine Language Language RoutineStrt TIM Start Lighting Conservation Setting lights off DST Daylight Saving Time SettingEnablex Lighting Conservation Control Enable Routine Strt DAY Day to Start SettingRefrig Refrigeration Routine Displyx POS Temperature Display Enable Routine Degrees Degree Fahrenheit / Celsius Setting RoutineStrt TIM Start Selection Blocking Routine Stop TIM Stop Selection Blocking Routine Strt DAY Day of Week Start SettingStop DAY Day of Week Stop Setting Select Selection To Be Affected By BlockingLightx Lighting / P.O.S. Display Control SELBLCK2 Block Selection Bank 2 RoutineDiscount Discount Setting Routine Override Manual Switch Override Routine Rvndmech Remote Vend Mechanism Routine Grabmode Grabmode Setting Routine Health Health Setting RoutineReturn Return to Sales Mode Enable X Health Enable RoutineRecheckx Recheck Feature Select Selections To Be Affected By Health ProtectionCOCA-COLA Programming Method Quick Reference Menu Prompts Cleaning PowerEprom Replacement Major Component Description Refrigeration UnitUniversal KO Board 0077-8272CB & Higher Universal KO Board prior to 0077-8272CB Programming Machine Board prior to 0077-8272CB Wiring Diagram 9 Column Wiring Diagram 6 Column Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Conveyor Issues Elevator Issues Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting Troubleshooting ICE / Frost on Evaporator Parts Index Machine Front View DN5000 DN3000 Part DescriptionCabinet Detail Cabinet Assembly Export Service Door Front CGF Coke DGF Dasani Glass Glass Front DN5000 & DN3000 Service Door FrontPart Number Part Description Service Door Inside DN5000 & DN3000 Service Door Inside Tray Assembly Gate Assembly with Kicker AC Distribution BOX Domestic Shown DN5000 & DN3000 AC Distribution BOX Elevator DN5000 & DN3000 Elevator Conveyor Conveyor Assembly Wiring not shown Lighting A1A Refrigeration DN5000 & DN3000 Refrigeration Electronics DN5000 & DN3000 Electronics Part Number Part Description NEW RemanufacturedHarnesses Part Part Description From / to NumberLabels / Decals / Misc CGF Coke DGF Dasani Glass FrontScrews and Nuts Screws & Nuts Screws & Nuts Washers / Bolts / Misc Hardware Washers , BOLTS, and MISC. Hardware Washers , BOLTS, and MISC. Hardware

DN5000, DN3000 specifications

The Maytag DN3000 and DN5000 are two robust commercial dishwashers designed to handle the rigorous demands of busy kitchens, making them ideal for restaurants, hotels, and catering operations. What sets these models apart is their combination of efficiency, performance, and durability, which are essential for maintaining high standards of cleanliness and sanitation.

Both the DN3000 and DN5000 feature an advanced wash system that ensures thorough cleaning of dishes, pots, pans, and utensils. The powerful wash pumps are designed to deliver optimal spray coverage, while the stainless steel construction enhances durability and corrosion resistance. This translates into longer-lasting equipment that can withstand the wear and tear of a high-volume environment.

In terms of capacity, the DN3000 can handle up to 300 racks per hour, while the DN5000 steps up the game with a capacity of 500 racks per hour. This makes the DN5000 particularly suited for establishments with heavy dishwashing loads, where speed and efficiency are paramount. Both models are equipped with a built-in booster heater that ensures optimal water temperatures for effective sanitization, which is critical for health and safety compliance.

User-friendly controls are another highlight of these dishwashers. The intuitive digital display allows operators to easily select wash cycles, monitor cycle progress, and troubleshoot issues. Additionally, both models feature automatic drain systems that help prevent clogs and reduce maintenance interruptions.

Energy and water efficiency are also key characteristics of the Maytag DN3000 and DN5000. These dishwashers are designed to minimize water consumption, making them environmentally friendly options that can help lower operational costs. With their ENERGY STAR certification, they meet energy-efficiency guidelines set by the U.S. Environmental Protection Agency.

Both models also come with customizable rack options to maximize washing effectiveness for various types of dishware, from flat dishes to larger pots and pans. Safety features like lockable controls and built-in safety interlocks further enhance operability, providing peace of mind for kitchen staff.

In summary, the Maytag DN3000 and DN5000 dishwashers are engineered for optimal performance in the fast-paced commercial kitchen setting. With their impressive capacity, advanced wash technology, user-friendly controls, and energy efficiency, these models are reliable choices for any food service operation looking to maintain high standards of cleanliness and efficiency.