SETTING THE BURNER MINIMUM

When switching from one type of gas to another, the minimum flow rate must also be cor- rect: the flame should not go out even when passing suddenly from maximum to minimum flame.

To regulate the flame (fig. 2.13) follow the instructions below:

Semirapid burner

Light the burner.

Set the gas valve to position (minimum rate).

Remove the knob.

With a thin screwdriver, turn the regulation screw “R1” until adjustment is correct.

Inside crown of DUAL burner

Light the DUAL burner.

Set the gas valve to position (minimum rate of inner crown).

Remove the knob

With a thin screwdriver, turn the regulation screw “R2” until adjustment is correct.

Outside crown of DUAL burner

Light the DUAL burner.

Set the gas valve to position (minimum rate of inner and outer crowns).

Remove the knob.

With a thin screwdriver, turn the regulation screw “R3” until adjustment is correct.

For LP/PROPANE gas, tighten the adjustment screws completely.

After regulation repeat the operations indicated in paragraph “2. PRESSURE REGULA- TOR” at page 12 and 15.

If the range has been disconnected and then connected again to the gas supply line repe- at the operations indicated in paragraph “5. LEAK TESTING” at page 15.

IMPORTANT:

After conversion to LP/PROPANE gas has been carried out affix near the data plate the conversion label supplied and also affix a conversion label at page 3 of this in- struction manual.

After conversion back to the original gas (NATURAL GAS) has been carried out re- move, near the data plate and at page 3 of this instruction manual, the LP/PROPANE conversion labels. Save the labels removed for future use.

R1 Regulation screw (Semirapid burner)

R2 Regulation screw (Inner crown of dual burner)

R3 Regulation screw (Outer crown of dual burner)

R3

R2

R1

Fig. 2.13

19

Image 19
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationAssembling the Backguard It is mandatory to install the backguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation Levelling the Range ANTI-TIP Stability Device Installation InstructionsInstalling the Cooktop Front Guard Pressure Regulator Manual Shut-off Valve figPressure Regulator Installation Step GAS Connection Specification Flexible Connections Leak TestingRigid Pipe Connections Setting the Pressure Regulator Fitting the warming drawer fig To set the pressure regulator figOrifices Table Operations to be Performed When Substituting the OrificesSemirapid burner Setting the Burner MinimumElectrical connection Electric Diagram KEY Wiring DiagramPage Cuisinière À GAZ/ÉLECTRIQUE Mise EN Garde Étiquette DE Conversion Avertissement Instructions D’INSTALLATIONPièces DE Rechange Instructions DE Mise À LA TerreProximité DES Armoires Montage DU Dosseret ’installation du dosseret est obligatoireProximité DES Armoires Installation Standard Proximité DES Armoires Installation EN Îlot Mise À Niveau DE LA Cuisinière Installation DU Dispositif DE Stabilité AntibasculementPage Régulateur de pression Robinet d’arrêt manuel figInstallation DU Régulateur DE Pression Étape Spécification DU Raccordement AU GAZ Raccords de tuyaux rigides Raccords flexiblesVérification de l’absence de fuite Réglage DU Régulateur DE Pression Pour régler le régulateur de pression fig Installation du tiroir de maintien au chaud figOpérations À Effectuer Pour Remplacer LES Injecteurs Tableau DES InjecteursBrûleur semi-rapide Réglage Minimum DU BrûleurRaccordement électrique Câbles P5B1+P5B2+P5B3 Schéma DE Câblage