TEST POINT ADAPTER

The Test Point adapter is available from the After-Sales Service.

Fig. 2.5

2

b.Any conversion required must be performed by your dealer or a qualified licen- sed technician or gas service company. Please provide the service person with this manual before work is started on the range. (Gas conversions are the re- sponsibility of the dealer or end user.)

c.This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with NATURAL gas.

d.Manifold pressure should be checked with a manometer and by operating as below detailed:

Remove the orifice from the rear left (or rear right) burner and mount the proper test point adapter which is available from the After-Sales Service (see side figure and the “OPERATIONS TO BE PERFORMED WHEN SUB- STITUTING THE ORIFICES” chapter).

Turn the rear left (or rear right) burner control knob to the maximum position.

Press the knob and keeping it pressed check the manifold pressure with a manometer; NATURAL gas requires 4.0” W.C.P. and LP/PROPANE requires 11.0” W.C.P.

Incoming line pressure upstream from the regulator must be 1” W.C.P. hi- gher than the manifold pressure in order to check the regulator.

The regulator used on this range can withstand a maximum input pressure of 1/2 PSI (14.0” W.C.P). If the line pressure is in excess of that amount, a stepdown regulator will be required.

e.The appliance, its individual shut-off valve, and pressure regulator must be di- sconnected from the gas supply piping system during any pressure testing of that system at pressures in excess of 1/2 PSI (3.5 kPa).

f.The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 1/2 PSI (3.5 kPa).

3. Flexible Connections:

If local codes permit, CSA or UL design-certified, flexible metal appliance connector is recommended for connecting this range to the gas supply line. Do Not kink or da- mage the flexible connector when moving the range. The pressure regulator has 1/2” NPT female pipe threads.You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve.

4. Rigid Pipe Connections:

If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the range. All strains must be removed from the supply and fuel lines so the range will be level and in line.

Use joint compounds and gaskets that are resistant to action of natural or propa- ne gas on all male pipe threads.

Do not over tighten gas fitting when attaching to the pressure regulator. Over tightening may crack the regulator.

5. Leak Testing:

IMPORTANT: Leak testing of the appliance shall be conducted as follows:

After final gas connection is made, turn on manual gas valve and test all con- nections in gas supply piping and appliance for gas leaks with a soapy water solution. During this test all appliance gas valves have to be closed.

In order to avoid property damage or serious personal injury, never use a Iighted match. If a leak is present, tighten joint or unscrew, apply more joint compound, tighten again and retest connection for leak.

15

Image 15
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationAssembling the Backguard It is mandatory to install the backguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation Levelling the Range ANTI-TIP Stability Device Installation InstructionsInstalling the Cooktop Front Guard Pressure Regulator Manual Shut-off Valve figPressure Regulator Installation Step GAS Connection Specification Leak Testing Flexible ConnectionsRigid Pipe Connections Setting the Pressure Regulator Fitting the warming drawer fig To set the pressure regulator figOrifices Table Operations to be Performed When Substituting the OrificesSemirapid burner Setting the Burner MinimumElectrical connection Electric Diagram KEY Wiring DiagramPage Cuisinière À GAZ/ÉLECTRIQUE Mise EN Garde Étiquette DE Conversion Avertissement Instructions D’INSTALLATIONPièces DE Rechange Instructions DE Mise À LA TerreProximité DES Armoires Montage DU Dosseret ’installation du dosseret est obligatoireProximité DES Armoires Installation Standard Proximité DES Armoires Installation EN Îlot Mise À Niveau DE LA Cuisinière Installation DU Dispositif DE Stabilité AntibasculementPage Régulateur de pression Robinet d’arrêt manuel figInstallation DU Régulateur DE Pression Étape Spécification DU Raccordement AU GAZ Raccords flexibles Raccords de tuyaux rigidesVérification de l’absence de fuite Réglage DU Régulateur DE Pression Pour régler le régulateur de pression fig Installation du tiroir de maintien au chaud figOpérations À Effectuer Pour Remplacer LES Injecteurs Tableau DES InjecteursBrûleur semi-rapide Réglage Minimum DU BrûleurRaccordement électrique Câbles P5B1+P5B2+P5B3 Schéma DE Câblage