1

GAS AND ELECTRIC CONNECTION

Dotted line showing the position

 

 

 

of the range when installed

Ref.

inch

mm

 

A

5” 7/16 - 6” 1/8 (*)

138 - 155.5 (*)

 

B

14” 3/8

365

 

 

 

 

 

C

37/64”

14.5

 

(*) : Depending on feet regulation

 

C

Area for

ELECTRICAL connection

BB

C

A

Area for

GAS connection

Fig. 1.2

A

ASSEMBLING THE BACKGUARD

It is mandatory to install the backguard.

Assemble the backguard as shown in figure 1.3:

Screw the 2 screws “A” interposing the spacers.

Screw the central screw “B”.

A

B

Fig. 1.3

7

Image 7
Contents GAS/ELECTRIC Range What to do if YOU Smell GAS Data Plate Conversion Label Installation Instructions Electrical Grounding Instructions Replacement PartsProximity to Side Cabinets InstallationAssembling the Backguard It is mandatory to install the backguardProximity to Side Cabinets Standard Installation Proximity to Side Cabinets Island Installation Levelling the Range ANTI-TIP Stability Device Installation InstructionsInstalling the Cooktop Front Guard Pressure Regulator Manual Shut-off Valve figPressure Regulator Installation Step GAS Connection Specification Flexible Connections Leak TestingRigid Pipe Connections Setting the Pressure Regulator Fitting the warming drawer fig To set the pressure regulator figOrifices Table Operations to be Performed When Substituting the OrificesSemirapid burner Setting the Burner MinimumElectrical connection Electric Diagram KEY Wiring DiagramPage Cuisinière À GAZ/ÉLECTRIQUE Mise EN Garde Étiquette DE Conversion Avertissement Instructions D’INSTALLATIONPièces DE Rechange Instructions DE Mise À LA TerreProximité DES Armoires Montage DU Dosseret ’installation du dosseret est obligatoireProximité DES Armoires Installation Standard Proximité DES Armoires Installation EN Îlot Mise À Niveau DE LA Cuisinière Installation DU Dispositif DE Stabilité AntibasculementPage Régulateur de pression Robinet d’arrêt manuel figInstallation DU Régulateur DE Pression Étape Spécification DU Raccordement AU GAZ Raccords de tuyaux rigides Raccords flexiblesVérification de l’absence de fuite Réglage DU Régulateur DE Pression Pour régler le régulateur de pression fig Installation du tiroir de maintien au chaud figOpérations À Effectuer Pour Remplacer LES Injecteurs Tableau DES InjecteursBrûleur semi-rapide Réglage Minimum DU BrûleurRaccordement électrique Câbles P5B1+P5B2+P5B3 Schéma DE Câblage
Related manuals
Manual 76 pages 28.62 Kb