B
WTMC Service Tips - - Test program (4B): Fault Codes
WTMC Dryer Test Program Fault Codes
Fault |
|
|
|
|
Code | Fault | Solution | Notes | Effect |
E:23 | Model variant doesn’t | Replace faulty control module. |
| Dryer stops & |
| match table |
|
| can’t be |
|
|
|
| restarted. |
E:24 | Software version | Replace faulty control module. |
| Dryer stops & |
| doesn’t match table |
|
| can’t be |
|
|
|
| restarted. |
E:25 | Damaged data table | Replace faulty control module. |
| Dryer stops & |
|
|
|
| can’t be |
|
|
|
| restarted. |
E:26 | Control error | Replace faulty control module. |
| Dryer stops & |
|
|
|
| can’t be |
|
|
|
| restarted. |
NOTE: Fault displayed alternates with # of times fault occurred every two (2) seconds. If there’s no faults, displays will be blank.
•E:xx = fault code from E11 – E39 (e.g. E:11)
•C:xx = # of occurrences (e.g. C:01)
NOTE: When test program is initially entered, last fault code will show. Display will be cleared once any test is started.