B
Error | Cause |
| Corrective Action |
|
|
|
|
F114 | Runaway lower temperature | 1. | Check P24 connector on the Power Board. |
| (>950°F) | 2. | Unplug the sensor connector and check lower sensor resistance |
| a) Intermittent or bad |
| (approximately 1080 ohms at room temperature with connector |
| temperature sensor. |
| removed). |
| b) Heating element relay stuck | 3. | If sensor is OK, replace Power Board. |
| on. | 4. | Check wiring to heating element. If OK, replace Power Board. |
|
|
|
|
F121 | Stuck keyboard key. | 1. | Check all connections between the display head (P5) and the |
| Bad display head or bad |
| keyboard (J1). |
| 2. | Make sure that there are no objects in close proximity to the front | |
| keyboard. |
| and back sides of the keypads. |
|
| 3. | Replace Display Board or keyboard or both. |
|
|
|
|
F123 | Keyboard disconnected | 1. | Check all connections between keyboard (J1) and Display Board |
| Bad connection between |
| (P5). |
| 2. | If OK, replace keyboard or Display Board or both. | |
| keyboard and Display Board. |
|
|
|
|
|
|
35