Thermador®
Thermador
Professional Ranges Models: PDR30/36/48…PRG30/36/48
The control continuously monitors system parameters for control and oven failures and reports a fault code when a system problem is detected. The control utilizes the ovens blue “on light” and oven “heating light” to report a detected fault code. The control will continue to flash the lights in the appropriate sequence as long as the fault exists.
Detection of a fault does not hinder the ability of the control to continue to function if the fault is not critical for the intended operation. For example: If the range door latch is inoperative, the range will continue to cook since the fault would only prevent the range from
ERROR CODE | LIGHT SEQUENCE CODE | DESCRIPTION |
|
|
|
E1 | 22 | EEPROM ERROR |
E2 | 01 | CONTROL NOT CALIBRATED |
E3 | 10 | SENSOR OPEN |
E4 | 12 | SENSOR SHORTED |
E5 | 21 | POTENTIONMETER FAILURE |
E6 | 32 | OVER |
E7 | 23 | OVER |
E9 | 43 | NO COOLING FANS |
E11 | 44 | DOOR LATCH FAULT |
E12 | 11 | EXP. BOARD NOT CONNECTED |
E13 | 13 | VCC LIFT OFF ERROR |
E14 | 55 | SELECTOR SWITCH ERROR |