Thermador®
S, SM, AND SMW Oven Error Code Messages – Updated 02/21/02
Error Code |
|
|
|
|
|
|
Displayed |
| Probable Cause |
| Example |
| Corrective Action |
F1 |
| Element Supervisor Enabled |
| Main power/relay |
| Replace main power/relay board |
|
|
| ||||
|
|
|
| board |
|
|
F1, F7 |
| Poor Connection Between Display |
| Intermittent Sensor |
| Replace control head kit & main power/relay |
|
| Head And Touch Panel |
| OR Main power/relay |
| board. See note 1. |
|
|
|
| board |
|
|
|
|
|
|
|
|
|
F2 |
| Oven Temperature Detected Or Door |
| Intermittent Sensor Or |
| Check oven latch switches & door light are |
|
| Light Coming On After 1 Hour Into |
| Main power/relay |
| operating properly. Check oven sensor from |
|
|
| board |
| molex plug on main power/relay board. | |
|
|
|
|
|
| Should read approximately 1050. |
F3 |
| Open oven sensor |
| Open Sensor Or |
| Check oven sensor from molex plug on main |
|
|
|
| Circuit Wiring |
| power/relay board. Should read approximately |
|
|
|
|
|
| 1050 ohms at room temperature. See note 3. |
|
|
|
|
|
| Check and make sure the temperature sensor |
|
|
|
|
|
| plug on the main power/relay board is in place |
|
|
|
|
|
| and not loose. |
12