STEP4: INSTALLINGANTI-TIPDEVICE

Parts Required for Installation of Anti-Tip Device:

PRG304 and PRG36 All Gas Ranges (Figures 9 and 10)

Thermador Part No.

Qty

Description

15-10-916

4

Screw, Phillips,#10 x 1-1/2"

15-10-771

1

Anti-Tip Channel, Adjust

 

 

able, PRG

15-10-772

1

Mounting Bracket, PRG

15-10-909

1

Bolt, Hex Head, 1/4"-20 x

 

 

1/2"

15-10-910

1

Nut, Hex, 1/4-20

15-10-911

2

Washer, Flat, 1/4-20

15-10-948

2

Screw, Phillips, #10 x 1/2"

FIG. 10 Adjustable Anti-Tip Channel PRG304

and PRG36 All-Gas Ranges

 

5-1/2"

This Hole

This Hole

For Flush

For Flush

Mount of

Mount of

PRG304

PRG36

1-9/32"

1-17/32"

FIG. 9 Mounting Kit for PRG304 and PRG36 All-Gas Ranges

Mounting Bracket

15-10-772 (1 Each)

15-10-909 (1 Each)

15-10-916 (4 Each)

15-10-771 (1 Each)

15-10-911 (2 Each)

15-10-910 (1 Each)

15-10-948 (2 Each)

FIG. 11 Mounting Kit for PRDS304 and PRDS36 Dual Fuel Ranges

15-10-770 (1 Each)

15-10-916 (4 Each)

than hardwood or metal.

Prepare holes at fastener locations as identified below:

PRDS304 and PRDS36 Dual Fuel Ranges (Figure 11)

Thermador Part No.

Qty

Description

15-10-916

4

Screw, Phillips,#10 x 1-1/2"

15-10-770

1

Anti-Tip Channel, Adjustable,

IMPORTANT INSTALLATION INFORMA- TION:

The anti-tip bracket may be attached to a solid wood cabinet having a minimum wall thickness of 3/4".

The thickness of the wall or floor may require use of longer screws, available at your local hardware store.

In all cases, at least two (2) of the bracket mounting screws must be fastened to solid

wood or metal.

Use appropriate anchors when fastening the mounting bracket to any material other

-For walls, wall studs, or floors composed of solid wood or metal, drill 1/8" pilot holes.

-For walls or floors composed of drywall, sheet-rock or other soft materials, drill 3/ 16" holes to a minimum depth of 1-3/4", then tap plastic anchors into each of the holes using a hammer.

-For walls or floors composed of concrete or concrete block, drill 3/16" holes to a minimum depth of 1-3/4", then tap con crete anchors into each of the holes using a hammer.

-For walls or floors having ceramic tile covering, drill 3/16" holes through the tile only, then drill into the material behind the tile as indicated immediately above.

If the range is moved to a new location, the Anti-Tip Device must be removed and rein- stalled.

Page 11

Image 13 Contents
Installationinstructionsmanual Professionalranges Table of Contents Introduction ImportantinstallationinformationFor Residential Use Only AvertissementsenfrancaisAvertissement Select Hood and Blower Models VentilationrequirementsCabinet Clearances CabinetpreparationCabinetpreparation Typ ELECTRICALSUPPLY,DUALFUELRANGES UNPACKING, Moving and Placingthe Range UNPACKING,MOVING and Placingthe Range WiresRange Tipping Hazard INSTALLINGANTI-TIPDEVICEElectrical Shock Hazard Property DamagePRDS304 and PRDS36 Dual Fuel Ranges Figure PRG304 and PRG36 All-Gas Ranges Figures 9, 10, 12a 12b PRDS304 and PRDS36 Dual-Fuel Ranges Figures 11, 14 Prds Wall Mount Hook UP GasrequirementsandhookupNatural Gas Requirements Propane Gas RequirementsChart D Power Supply Wire Rating and Size Requirements Chart C Electrical Supply Circuit RequirementsELECTRICALREQUIREMENTS,CONNECTION&GROUNDING Location of Junction Box On PRDS304 Range Conductor Securement Do not Ground to a GAS Supply Pipe See . This method is not recommendedChart D Backguard KIT Model Numbers BackguardinstallationELECTRICALREQUIREMENTS,CONNECTIONS&GROUNDING Step TestandadjustmentGriddle Grill To Clean and Protect Exterior SurfacesFinal Check List InstallerchecklistGAS Supply ElectricalPage