Thermador PRDS48, PRG48 PRG304 and PRG36 All-Gas Ranges Figures 9, 10, 12a 12b

Page 14

STEP4: INSTALLINGANTI-TIPDEVICE

PRG304 AND PRG36 All-Gas Ranges (Figures 9, 10, 12a 12b and 13)

STEP A: Determine the best location for the PRG Mounting Bracket. The bracket may be mounted to the wall or floor behind the range, offset from either the left or right side wall by 2-3/4" for model PRG304 or

4-5/8" for Model PRG36.

-Locate the bracket on the side of the range that will not interfere with the gas supply line, electrical wiring, conduit or any other item.

-Select either the rear wall or the floor for mounting the bracket, based upon which will provide the greatest holding strength.

STEP B: Set the bracket on the floor and turn it until it is oriented properly. The bracket should be standing up on end. The set of mounting flanges having one (1) hole per side should be resting on the floor, and the other set of mounting flanges having two (2) holes per side should be positioned vertically facing the rear.

STEP C: Slide the bracket left or right to the correct position for the model that you are installing. The distance from the side wall to the center line of the closest mounting hole is 2-3/4"

FIG. 12a PRG36 Wall Mount (0" Clearance)

PLAN VIEW

PRG304: 2-3/4"

PRG36: 4-5/8"

May Be Used On Either Left or Right Side (Right Shown)

SIDEVIEW

FIG. 12b PRG Wall Mount (Max 2" Clearance)

for model PRG304 or 4-5/8" for Model PRG36.

STEP D: If you plan to mount the bracket to the rear wall, slide the bracket back until it is positioned against the rear wall. If you plan to mount the bracket to the floor, position the bracket such that the center line of the mount- ing holes in the horizontal bracket flanges are 7/16" in front of the rear edge of the range side panel when the range is in its final in- stalled position.

PLAN VIEW

May Be Used On Either Left

PRG304: 2-3/4"

PRG36: 4-5/8"

Maxi-

or Right Side (Right Shown)

m u m

STEP E: With the bracket properly positioned, use the bracket as a template and mark the location of the selected mounting holes in either the rear wall l (4 holes) or the floor (2 holes) with a pencil.

STEP F: Drill holes at the marked locations.

STEP G: Using the screws provided, securely fasten the bracket to the rear wall (4 screws) or floor (2 screws).

Up to 2"

SIDEVIEW

Page 12

Image 14 Contents
Installationinstructionsmanual Professionalranges Importantinstallationinformation Table of Contents IntroductionAvertissementsenfrancais For Residential Use OnlyAvertissement Ventilationrequirements Select Hood and Blower ModelsCabinetpreparation Cabinet ClearancesCabinetpreparation Typ ELECTRICALSUPPLY,DUALFUELRANGES UNPACKING, Moving and Placingthe Range Wires UNPACKING,MOVING and Placingthe RangeElectrical Shock Hazard INSTALLINGANTI-TIPDEVICERange Tipping Hazard Property DamagePRDS304 and PRDS36 Dual Fuel Ranges Figure PRG304 and PRG36 All-Gas Ranges Figures 9, 10, 12a 12b PRDS304 and PRDS36 Dual-Fuel Ranges Figures 11, 14 Prds Wall Mount Natural Gas Requirements GasrequirementsandhookupHook UP Propane Gas RequirementsELECTRICALREQUIREMENTS,CONNECTION&GROUNDING Chart C Electrical Supply Circuit RequirementsChart D Power Supply Wire Rating and Size Requirements Location of Junction Box On PRDS304 Range Conductor Securement See . This method is not recommended Do not Ground to a GAS Supply PipeELECTRICALREQUIREMENTS,CONNECTIONS&GROUNDING BackguardinstallationChart D Backguard KIT Model Numbers Testandadjustment StepTo Clean and Protect Exterior Surfaces Griddle GrillGAS Supply InstallerchecklistFinal Check List ElectricalPage