56CHAPTER 4: PROBLEM SOLVING

If a fan failure warning message is generated:

1Power off the unit.

2Check that the air vents are not obstructed.

3Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC main supply, remove and reconnect the DC RPS supply.

4If another fan failure warning message is generated via the Command Line Interface or the Web interface, return the unit.

Unit fails, no SNMP fan failure message is received

1Power cycle the unit. To do this, remove and reconnect the AC mains supply. If the unit has no AC mains supply, remove and reconnect the DC RPS supply.

2Check the command line interface (system summary command) to determine whether a thermal shutdown has occurred.

3If no, return the unit: If yes, check that:

The air vents are not obstructed.

The ambient temperatures and environmental conditions meet those specified in Appendix C.

4Power cycle the unit. If a further thermal shutdown occurs, and all environmental conditions are satisfactory, return the unit to 3Com.

Error message indicating that the GBIC transceiver is invalid

The Switch has identified that the GBIC does not meet the minimum requirements for the Switch and has disabled the port. To correct this problem, completely remove the GBIC and replace it with a 3Com approved GBIC. See “Approved GBIC Transceivers”on page 29

Error message indicating that the GBIC transceiver is faulty

To correct this problem, completely remove the GBIC and then reinsert it. If the problem persists, contact 3Com Technical Support.