Thermador P30 Important Installation Information, GAS type verification, Gas Supply

Page 4

Important Installation Information

GAS type verification

Verify the type of gas supplied to the location. Ensure that the appliance is connected to the type of gas for which it is certified. Ranges are certified for use with only natural gas or propane (LP) gas. Make certain the range matches the gas type available; these ranges are NOT convertible between gas types.

WARNING

To avoid possible burn or fire hazard, a backguard designed specifically for this range must be installed whenever the range is used.

Refer to the Backguard Installation instructions on page 14, for the correct backguard models that are designed for this range. After selecting the correct backguard, the range must be installed properly, using the minimum clearances to com- bustible surfaces specified in the Cabinet Prepa- ration instructions on pages 4 and 5.

Important

A backguard must be utilized when there is less than a 12” horizontal clearance between combus- tible materials and the back edge of the range. The Thermador Low Back backguard must be or- dered separately and installed at the rear of the range. For island installations and other installa- tions with more than 12” clearance, an optional stainless steel Island Trim is available to cover the backguard mounting flanges.

Verify that the appliance is correct for the type of gas being provided. Refer to Step 5 on Page 12 before proceeding with the installation.

CAUTION

To eliminate risk of burns or fire caused by reaching over heated surface units, cabinet storagelocatedabovethesurfaceunitsshould be avoided.

Gas Supply:

Natural Gas – 6 inch water column. (14.9 mb) min., 14 inch (34.9 mb) maximum

Propane Gas – 11 inch water column. (27.4 mb) min., 14 inch (34.9 mb) maximum

Electric Power Supply:

30" Model:

4 Burners - 120 VAC, 60 Hz., 1Ph., 10 Amp circuit. 36" Models:

6 Burners – 120 VAC, 60 Hz., 1Ph., 10 Amp circuit.

4 Burners with Grill – 120 VAC, 60 Hz., 1Ph., 10 Amp circuit. 4 Burners with Griddle – 120 VAC, 60 Hz., 1Ph., 20 Amp circuit.

CAUTION

When connecting the unit to propane gas, make certain the propane gas tank is equipped with its own high-pressure regulator in addition to the pressure regulatorsuppliedwiththerange.Themaximumgas pressure to this appliance must not exceed 14.0 inches water column (34.9 mb) from the propane gas tank to the pressure regulator.

CAUTION

This unit is designed as a cooking appliance. Based on safety considerations, never use it for warming or heating a room.

This appliance has been tested in accordance with ANSI Z21.1, Standard for Household Cooking Appli- ances (USA) and in accordance with CAN 1.1-M81 Domestic Gas Ranges (Canadian).

It is strongly recommended that this appliance be installed in conjunction with a suitable overhead vent hood. (See Step 1 for Ventilation Requirements.) Due to the high heat capability of this unit, particular atten- tion should be paid to the hood and duct work instal- lation to assure it meets local building codes.

This appliance complies with one or more of the following standards:

UL 858, Standard for the Safety of Household Electric Ranges

UL 923, Standard for the Safety of Microwave Cooking Appliances

UL 507, Standard for the Safety of Electric Fans

ANSI Z21.1, American National Standard for Household Cooking Gas Appliances

CAN/CSA-C22.2 No. 113-M1984 Fans and Venti- lators

CAN/CSA-C22.2 No. 61-M89 Household Cooking Ranges

Check local building codes for the proper method of appliance installation. Local codes vary. Installation, electrical connections and grounding must comply with all applicable codes. In the absence of local codes the appliance should be installed in accor- dance with the National Fuel Gas Code ANSI Z223.1/ NFPA 54 current issue and National Electrical Code ANSI/NFPA 70 -current issue. In Canada, installation must be in accordance with the CAN 1-B149.1 and .2

Installation Codes for Gas Burning Appliances and/ or local codes.

It is the responsibility of the owner and the installer to determine if additional requirements and/or standards apply to specific installations.

1

Image 4
Contents Installation Instructions For Massachusetts Installations Do Not install this range outdoorsPlease Read Entire Instructions Before Proceeding What to do if YOU Smell GASContents Important Installation Information Electric Power SupplyGAS type verification Gas SupplyHood Placement Ventilation RequirementsSelect Hood and Blower Models Consider Make-Up AirCabinet Preparation Cabinet Clearances Side View GAS and Electric Supply Gas & Electrical Supply Locations for All Gas RangesElectrical SUPPLY, ALL GAS Ranges Wall ConnectionUnpacking, Moving and Placing the Range Removal of the Four 4 Shipping BoltsGrill/Griddle Tilt Adjustment Not All Models Installing Anti-Tip Device Tools Needed for Installation of Anti-Tip DeviceRange Tipping Hazard Property Damage36 Ranges Figures 6 Important Installation InformationMounting ANTI-TIP Bracket Hook UP Gas Requirements and HookupPhoto a Chart B Electrical Supply Circuit Requirements Electrical Requirements, Connection & GroundingChart C Backguard Kit Model Numbers Backguard InstallationFront of Range To Reinstall the Oven Door Door Removal and ReinstallationTo Remove the Oven Door Flame Characteristics Burner Test and AdjustmentTest Rangetop Burners Flame Adjustment if necessary Test Oven BurnersTest Bake Burner Ignition Test Broil Burner IgnitionFinal Check List GAS SupplyElectrical OperationPage NE PAS installer cette gamme dehors Pour les installations au MassachusettsAvertissement Table des matières Informations importantes à propos de linstallation Mise EN GardeChapitre 1 Exigences pour la ventilation Emplacement de la hotteApport d’air Chapitre 2 Préparation de l’emplacement Dégagement des armoires Vue latérale RemarqueAlimentation DE GAZ ET Électrique RemarqueAlimentation électrique pour toutes les cuisinières au gaz Cordon d’alimentation et prisePallette Réglage de langle du gril/grille certains modèles Avertissement Danger DE Basculement Chapitre 4 Installation du dispositif antibasculeAvertissement Risque D’ÉLECTROCUTION Cuisinières à gaz de 30 po et 36 po Figures 6 et Informations Importantes À Propos DE L’INSTALLATIONMontage DE LA Patte Antibascule Exigences pour le gaz naturel RaccordementExigences pour le gaz propane Modèle Tension Intensité DU Circuit Fréquence Phase Chapitre 7 Installation du dosseret Tableau C numéro de modèle de dosseretChapitre 8 Retrait et installation de la porte Installation de la porteFaire Attention Pour Retirer LA PORTE, Elle EST Lourde Retrait de la porteVérifier les brûleurs de surface Chapitre 9 Test et réglage de brûlerVérifier la flamme. Réglage bas. Tourner le bouton Vérifier les brûleurs du four Réglage de flamme au besoinVérifier lallumage du gril Réglage de l’obturateur d’airListe de vérification pour l’installateur Liste Finale DE VérificationAlimentation EN GAZ ÉlectricitéRemarques

P30 specifications

The Thermador P30 is a premium wall oven designed for culinary enthusiasts who demand precision, performance, and luxury in their kitchen. This standout appliance exemplifies Thermador’s commitment to innovation, offering a host of features and technologies that elevate the cooking experience.

One of the key features of the Thermador P30 is its powerful convection cooking system. This technology uses a fan and a third heating element to circulate hot air evenly throughout the oven, ensuring that every dish is cooked uniformly. This method not only enhances cooking efficiency but also significantly reduces cooking times, allowing users to prepare meals faster without compromising on quality.

The P30 also boasts a 10 culinary modes feature, which grants home cooks the ability to choose from various cooking settings specifically designed for specific types of dishes. Whether it’s baking, broiling, or roasting, each mode optimizes the oven’s performance to deliver perfect results. The precise temperature control ensures that even the most delicate recipes achieve professional-level outcomes.

Another highlight is the Wi-Fi connectivity that the Thermador P30 offers. Users can control and monitor their oven remotely through a smartphone app, allowing for seamless multitasking in the kitchen. This feature also includes voice control compatibility with smart home systems, providing added convenience for busy cooks.

The P30 is equipped with an elegant, touch-sensitive control panel that provides an intuitive interface, making navigation simple and straightforward. Its sleek design embodies modern kitchen aesthetics, with a tempered glass door that allows users to monitor cooking progress without losing heat.

Furthermore, ease of cleaning is a significant characteristic of the Thermador P30. The self-cleaning mode simplifies maintenance by using high temperatures to burn away food residue, allowing for a spotless interior without labor-intensive scrubbing.

Space optimization is another consideration. With a generous capacity, the Thermador P30 can accommodate multiple dishes simultaneously, making it ideal for entertaining or family meals. The oven is designed to be installed in various kitchen configurations, enhancing flexibility in layout.

Overall, the Thermador P30 is a sophisticated appliance that combines cutting-edge technology with user-friendly features and elegant design. It meets the demands of modern home chefs while providing the reliability and performance expected from a luxury brand. Whether baking a cake or roasting a turkey, the P30 ensures every culinary endeavor is executed to perfection, making it a valuable addition to any kitchen.