Thermador HMWB30, HMWB36 installation manual Installing the Hood

Page 5

Parts In cluded with your Hood

tHood Canopy Assembly with blower already installed

tGrease filters

tDrip tray for each filter.

tDrip trays holding brakets + plastic wahers and knobs

t1 Transition withback draft damper

tUse & Care / Installation Instructions

tFittings bag with:

4 Washers

6 Drywall anchors

2 Hooks with regulating screws

6 Screws 5X35

4 Screws for transition

Option al accessory

Duct covers

Ductless recirculation kit available only for HMWB30, HMWB36. model.

Parts Not Included with your

Hood

tDuct Tape

t1/2" Conduit

tWire Nuts

tRound Duct.

tWiring c lamp

t

CAUTION! Lamps are not supplied, use

 

ONLY 120 Volt, 50 Watt (maximum) 50°

 

halogen light made o r a GU10 base,

 

suitable for use i n open luminarie .

t4 #10 pan head wood screws for installation on a bottom of a cabinet

t3 prong plug

Tools required

Flat blade and Phillips screwdrivers

Pencil and tape measure

Metal snips (in some applications)

Electric drill

Saw (saber or keyhole)

Pliers

Level

Caulking

Flashlight

Wire stripper

Safety glasses

Gloves

Step ladder

INSTALLING THE HOOD

tFor the most efficient air flow exhaust, use a straight run or as few elbows as possible.

CAU TIO N: Vent unit to outside o f building, only.

tTwo people are necessary for installation.

On average 2 hours are necessary to complete installation (without considering cut to be done on wall and or on cabinet, installation of ducts , conduit and electrical connections to the mains) . installation steps:

11 installation steps are required for both installation methods

Wall mount installation steps or in alternative Cabinet installation

tThe hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly f it with your cabinet/wall.

tDo not use flex ducting.

t COLD WEATHER installations should have an additional backdraft damper i nstalled to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break.

The break should be as close as possible to where the ducting enters the heated portion of the house.

tMake up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than

specified CFM of air movement.

The specified CFM varies from location to. location Consult your HVAC professional for specific requirements in your area.

5

Image 5
Contents N T I L AT I O N Install Ation Manual Page Important Safety Instructions Electrical requirements Installing the Hood Choose vent options  Typical installationVentilator performance calculation Transition Screws Wall Mount Installation For both ins tallation method Importantes Instructions DE Sécurité Importantes Instructions DE Securité Spécifications pour l’installation élec- triquePièces non fournies avec votre hotte Installation DE LA HotteExemples de possibles types d’extraction/evacuation Installation typiqueTabla 1. Calcul de performances de ventilation Ajustage/dimensionsVisses Installation SUR MUR Figura Advertencia Requerimientos eléctricos Instrucciones DE Seguridad ImportantesInstalando LA Campana Ejemplos de posible intalación Tabla 1. Cálculo de funcionamiento de Ventilación Transición Tornillos Instalación en gabinete Instalación a paredInstrucciones Para Tierra Electrica