Alto-Shaam 750-TH-II RISK of ELEcTrIc SHOcK, Appliance must be secured To building structure

Page 10

i n s t a l l a t i o n

s i t e INSTALLATION

A number of adjustments are associated with initial installation and start-up. It is important that these adjustments be conducted by a qualified service technician. Installation and start-up adjustments are the responsibility of the dealer or user. These adjustments include but are not limited to thermostat calibration, door adjustment, leveling, electrical hook-up and installation of optional casters or legs.

LEVELING

Level the oven

from side-to-side and front-to-back

with the use of a spirit level. For ovens installed with casters, it is important that the installation surface be level due to the probability of frequent oven repositioning.

We recommend checking the level of the oven periodically to make certain the floor has not shifted nor the oven moved.

NOTE: Failure to properly level this oven can cause improper function and will result in the uneven baking with products consisting of semi-liquid batter.

RESTRAINT REQUIREMENTS —MOBILE EQUIPMENT

WArNING

rISK OF ELEcTrIc SHOcK.

Appliance must be secured

to building structure.

Any appliance that is not furnished with a power supply cord but that includes a set of casters must be installed with a tether. Adequate means must be provided to limit the movement of this appliance without depending on or transmitting stress to the electrical conduit. The following requirements apply:

1.Casters must be a maximum height of 6" (152mm).

2.Two of the casters must be the locking type.

3.Such mobile appliances or appliances on mobile stands must be installed with the use of a flexible connector secured to the building structure.

A mounting connector for a restraining device is located on the upper back flange of the appliance. A flexible connector is not supplied by nor is it available from the factory.

TH-IIseries installation/operation/service manual - pg. 8

Image 10 Contents
Installation Sanitation L I V E r y P a c K I N GSAFETy prOcEdurES PrEcAuTIONS N G E rSite Installation Minimum clearance Requirements TH-II 1000-TH/II 127mm 5004862 5010371 50097674459 5010948Stacking Configurations STAcKING INSTrucTIONSAppliance must be secured To building structure RISK of ELEcTrIc SHOcKCasters must be a maximum height of 6 152mm Drip tray installation instructions Hard wired models Ectrical ConnectionSEVErE dAMAGE Or ELEcTrIcAL HAZArd COuLd rESuLT 300F 149C60 to 205F 16 to 96C 200 to 325F 94 to 160CGeneral Holding Guideline 16 to 93C. If the unit is equipped with vents, closePrOTEcTING Stainless Steel SurFAcES CLEANING AgentsCLEANING MATErIALS Acid muriatic acid on stainless steel surfacesClean the Door Vents Sa n i t a t i o n Error Code Description Possible cause To test probe and air sensorTH-II shown ERV ICE Electronic Components parts list 500-TH/III 230V shownCable Heating Service KitS Cable heating service kit #4880 #4881Page   Page  Transportation Damage and Claims Voltage Purchased From