Alto-Shaam 750-TH-II manual Site Installation, Minimum clearance Requirements

Page 5

i n s t a l l a t i o n

d A N G E r

IMPROPER INSTALLATION,

ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE.

READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT.

c A u T I O N

TO PREVENT PERSONAL INJURY, USE CAUTION WHEN MOVING OR LEVELING THIS APPLIANCE.

c A u T I O N

METAL PARTS OF THIS EQUIPMENT BECOME EXTREMELY HOT WHEN IN OPERATION. TO AVOID BURNS, ALWAYS USE HAND PROTECTION WHEN OPERATING THIS APPLIANCE.

dANGEr

DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance.

The Alto-Shaam cook and hold oven must be installed in a location that will permit the oven to function

for its intended purpose and to allow adequate clearance for ventilation, proper cleaning, and maintenance access.

1.The oven must be installed on a stable and level surface.

2.DO NOT install this oven in any area where it may be affected by any adverse conditions such as steam, grease, dripping water, high temperatures, etc.

3.DO NOT store or use any flammable liquids or allow flammable vapors in the vicinity of this oven or any other appliance.

4.This appliance must be kept free and clear of any combustible materials.

5.This appliance must be kept free and clear of any obstructions blocking access for maintenance or service.

SITE INSTALLATION

Emissions testing conducted by Underwriters Laboratories, Inc.® was found to be in compliance with the applicable requirements of NFPA96: 2004 Edition, Par. 4.1.1.2. U.L emissions sampling

of grease laden vapor resulted in a total of 0.55 milligrams per cubic meter with no visible smoke and is considered representative of all oven models in the line. Based on these results, hood installation and/or outside venting should not be a requirement in most areas. Verify local codes for locations where more restrictive codes are applicable.

Minimum clearance REQUIREMENTS

 

combustible

non-combustible

 

s u r f a c e s

surfaces

 

 

 

back

3" (76mm)

3" (76mm)

left side

1" (25mm)

1" (25mm)

right side

1" (25mm)

1" (25mm)

top

2" (51mm)

2" (51mm)

TH-IIseries installation/operation/service manual - pg. 3

Image 5 Contents
Installation Sanitation P a c K I N G L I V E r yN G E r SAFETy prOcEdurES PrEcAuTIONSMinimum clearance Requirements Site InstallationTH-II 1000-TH/II 4459 5010371 5009767127mm 5004862 5010948STAcKING INSTrucTIONS Stacking ConfigurationsCasters must be a maximum height of 6 152mm RISK of ELEcTrIc SHOcKAppliance must be secured To building structure Drip tray installation instructions Ectrical Connection Hard wired models300F 149C SEVErE dAMAGE Or ELEcTrIcAL HAZArd COuLd rESuLT200 to 325F 94 to 160C 60 to 205F 16 to 96C16 to 93C. If the unit is equipped with vents, close General Holding GuidelineCLEANING MATErIALS CLEANING AgentsPrOTEcTING Stainless Steel SurFAcES Acid muriatic acid on stainless steel surfacesClean the Door Vents Sa n i t a t i o n To test probe and air sensor Error Code Description Possible causeTH-II shown ERV ICE 500-TH/III 230V shown Electronic Components parts listCable heating service kit #4880 #4881 Cable Heating Service KitSPage   Page  Voltage Purchased From Transportation Damage and Claims